An in vitro biomechanical comparison of the insertion variables and pullout mechanical properties of ao 6.5-mm standard cancellous and 7.3-mm self-tapping, cannulated bone screws in foal femoral bone
- PMID: 15659027
- DOI: 10.1111/j.1532-950x.2004.04093.x
An in vitro biomechanical comparison of the insertion variables and pullout mechanical properties of ao 6.5-mm standard cancellous and 7.3-mm self-tapping, cannulated bone screws in foal femoral bone
Abstract
Objective: To compare screw insertion variables and pullout mechanical properties between AO 6.5-mm cancellous and 7.3-mm cannulated bone screws in foal femoral bone.
Study design: A paired, in vitro mechanical study.
Sample population: Seven pairs of femora from immature (1-7 months) foals.
Methods: The 6.5 cancellous and 7.3-mm cannulated screws were inserted at standardized proximal and distal metaphyseal, and mid-diaphyseal locations. Insertion torque, force, and time to drill, tap (6.5-mm cancellous), guide wire insertion (7.3-mm cannulated), and screw insertion were measured. Screw pullout properties (yield and failure load, displacement, and energy, and stiffness) were determined from mechanical tests. The effects of screw type and location on insertion variables and pullout properties were assessed with repeated measures ANOVA. Pairwise comparisons were examined with post hoc contrasts. Significance was set at P<.05 for all comparisons.
Results: Insertion torques for the 7.3-mm cannulated screws were significantly greater than for the 6.5-mm tap, but significantly lower than for the 6.5-mm cancellous screws. Total screw insertion times were similar. Pullout properties of both screws were similar at each femoral location. The holding power of both screws was significantly greater in the mid-diaphysis than in either metaphyseal location. Pullout failure occurred by bone shearing at the bone-screw interface in all specimens.
Conclusions: The 6.5-mm cancellous and 7.3-mm cannulated screws vary in insertion properties, but have similar pullout properties in the mid-diaphysis, proximal, and distal metaphysis of foal femora. Both screw types have greater holding power at the mid-diaphyseal location compared with metaphyseal locations. Based on overall similar holding powers of 6.5-mm cancellous and 7.3-mm cannulated screws, it is unlikely that increasing the screw diameter beyond 6.5 mm will provide increased holding power in foal femoral bone.
Clinical relevance: Use of the 7.3-mm cannulated screw should be considered for foal femoral fracture repair when greater accuracy is needed, or when bone threads for the 6.5-mm cancellous screw have been stripped.
Similar articles
-
A biomechanical comparison of headless tapered variable pitch and AO cortical bone screws for fixation of a simulated slab fracture in equine third carpal bones.Vet Surg. 2003 Mar-Apr;32(2):167-77. doi: 10.1053/jvet.2003.50019. Vet Surg. 2003. PMID: 12692762
-
A biomechanical comparison of headless tapered variable pitch compression and ao cortical bone screws for fixation of a simulated midbody transverse fracture of the proximal sesamoid bone in horses.Vet Surg. 2004 May-Jun;33(3):253-62. doi: 10.1111/j.1532-950X.2004.04037.x. Vet Surg. 2004. PMID: 15104632
-
Comparison of insertion time and pullout strength between self-tapping and non-self-tapping AO 4.5-mm cortical bone screws in adult equine third metacarpal bone.Vet Surg. 2002 May-Jun;31(3):189-94. doi: 10.1053/jvet.2002.32398. Vet Surg. 2002. PMID: 11994845
-
Stabilization of a proximal femoral physeal fracture in a filly by use of cancellous bone screws.J Am Vet Med Assoc. 1992 Sep 15;201(6):895-8. J Am Vet Med Assoc. 1992. PMID: 1399801
-
Mechanical evaluation of a 4-mm cancellous "rescue" screw in osteoporotic cortical bone: a cadaveric study.J Orthop Trauma. 2010 Jun;24(6):379-82. doi: 10.1097/BOT.0b013e3181c29bde. J Orthop Trauma. 2010. PMID: 20502222
Cited by
-
Optimizing Subtalar Arthrodesis: A Human Cadaveric Evaluation of a Novel Partially-Threaded Screw Combination in the Delta Configuration.Medicina (Kaunas). 2024 May 22;60(6):844. doi: 10.3390/medicina60060844. Medicina (Kaunas). 2024. PMID: 38929461 Free PMC article.
-
Is a Washer a Mandatory Component in Young Trauma Patients with S1-S2 Iliosacral Screw Fixation of Posterior Pelvis Ring Injuries? A Biomechanical Study.Medicina (Kaunas). 2023 Jul 28;59(8):1379. doi: 10.3390/medicina59081379. Medicina (Kaunas). 2023. PMID: 37629669 Free PMC article.
-
[The biomechanical study to evaluate tightening condition for AO lag screw depending on pull-out strength and interfragmentary compressive force].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2017 Dec 1;34(6):863-868. doi: 10.7507/1001-5515.201609073. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2017. PMID: 29761980 Free PMC article. Chinese.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous