Ceramics in total hip replacement
- PMID: 15662305
- DOI: 10.1097/01.blo.0000149996.91974.83
Ceramics in total hip replacement
Abstract
Alumina-on-alumina total hip arthroplasty has been used for 32 years in Europe. The theoretical advantages of this combination are represented by its remarkable sliding characteristics, its very low wear debris generation, and its improved fracture toughness. These advantages are achieved if the material is processed properly with high density, high purity and small grains. We summarize the results obtained with the alumina-on-alumina combination concerning in vitro and in vivo wear behavior with special emphasis on wear debris characterization and quantification and histologic tissue examinations. Alumina-on-alumina seems to be one of the best choices in young and active patients provided that sound socket fixation is maintained in the long term.
Similar articles
-
Ceramic/ceramic total hip arthroplasty.J Orthop Sci. 2000;5(6):622-7. doi: 10.1007/s007760070017. J Orthop Sci. 2000. PMID: 11180930 Review.
-
Bearing couples in total hip arthroplasty.Br J Hosp Med (Lond). 2010 Aug;71(8):446-50. doi: 10.12968/hmed.2010.71.8.77667. Br J Hosp Med (Lond). 2010. PMID: 20852486 Review.
-
Polyethylene wear and osteolysis after cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearings in patients younger than thirty years of age.J Bone Joint Surg Am. 2013 Jun 19;95(12):1088-93. doi: 10.2106/JBJS.L.01211. J Bone Joint Surg Am. 2013. PMID: 23783205
-
Alternative materials to improve total hip replacement tribology.Acta Orthop Scand. 2003 Aug;74(4):380-8. doi: 10.1080/00016470310017668. Acta Orthop Scand. 2003. PMID: 14521286 Review.
-
Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.Int Orthop. 2011 Feb;35(2):207-13. doi: 10.1007/s00264-010-1187-1. Epub 2010 Dec 30. Int Orthop. 2011. PMID: 21191579 Free PMC article. Review.
Cited by
-
Is there a risk in placing a ceramic head on a previously implanted trunion?Clin Orthop Relat Res. 2010 Dec;468(12):3322-7. doi: 10.1007/s11999-010-1505-3. Clin Orthop Relat Res. 2010. PMID: 20700672 Free PMC article.
-
Comparison of ceramic-on-ceramic bearing vs ceramic-on-highly cross-linked polyethylene-bearing surfaces in total hip arthroplasty for avascular necrosis of femoral head: a prospective cohort study with a mid-term follow-up.J Orthop Surg Res. 2019 Nov 27;14(1):388. doi: 10.1186/s13018-019-1410-8. J Orthop Surg Res. 2019. PMID: 31775827 Free PMC article.
-
Designing functionally graded materials with superior load-bearing properties.Acta Biomater. 2012 Mar;8(3):1101-8. doi: 10.1016/j.actbio.2011.11.033. Epub 2011 Dec 6. Acta Biomater. 2012. PMID: 22178651 Free PMC article.
-
The influence of the centre of rotation on implant survival using a modular stem hip prosthesis.Int Orthop. 2009 Dec;33(6):1513-8. doi: 10.1007/s00264-008-0710-0. Epub 2008 Dec 20. Int Orthop. 2009. PMID: 19099304 Free PMC article.
-
Total hip arthroplasty in patients 55 years or younger: Risk factors for poor midterm outcomes.J Clin Orthop Trauma. 2018 Apr-Jun;9(2):103-106. doi: 10.1016/j.jcot.2016.12.009. Epub 2017 Feb 9. J Clin Orthop Trauma. 2018. PMID: 29896009 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical