Evaluation of the NucliSens EasyQ assay in HIV-1-infected individuals in South Africa
- PMID: 15664057
- DOI: 10.1016/j.jviromet.2004.11.009
Evaluation of the NucliSens EasyQ assay in HIV-1-infected individuals in South Africa
Abstract
We compared the performance of the NucliSens EasyQ assay (bioMerieux) combined with the manual NucliSens miniMag extraction methodology to the Roche Cobas Ampliprep/Standard Amplicor Monitor methodology (Roche Diagnostics) for HIV-1 RNA quantitation in HIV-1-infected individuals in South Africa. Plasma samples (284) from HIV sero-positive patients at different stages of infection were analyzed. The distribution of results was typical of the clinical samples received at the laboratory where 20% have viral load results <400 copies/ml (2.6 log) and 18% have viral load results >750000 copies/ml (5.8 log) using the Roche Amplicor Monitor standard assay. All statistical analyses were performed using log10-transformed values for all the variables in the analyses, i.e. log10EasyQIU/ml, and log10RNA (log10 copies/ml, Amplicor). Roche values were converted from RNA copies per ml to IU/ml by multiplying the Roche value by 0.51. HIV RNA levels quantitated by the NucliSens EasyQ assay correlated significantly with those of the Roche Cobas Amplicor Monitor assay (r=0.874, p<0.0001). Reproducibility of the NucliSens EasyQ assay in the log6IU range yielded CV variance of 1.3-2.84% for two well-trained technologists. In addition, a retrospective evaluation of the performance of the NucliSens EasyQ assay in 102 runs (2448) samples was conducted in the laboratory over a 4-month interval. Factors considered during this evaluation included time taken to perform the assay, volume requirements, number of required repeats, potential for contamination.
Similar articles
-
Evaluation of NucliSens EasyQ HIV-1 assay for quantification of HIV-1 subtypes prevalent in South-east Asia.J Clin Virol. 2007 Jan;38(1):39-43. doi: 10.1016/j.jcv.2006.10.002. Epub 2006 Nov 15. J Clin Virol. 2007. PMID: 17110162
-
Multicenter evaluation of the NucliSens EasyQ HIV-1 v1.1 assay for the quantitative detection of HIV-1 RNA in plasma.J Virol Methods. 2005 Jul;127(1):54-9. doi: 10.1016/j.jviromet.2005.03.013. Epub 2005 Apr 25. J Virol Methods. 2005. PMID: 15893566
-
Evaluation of the performance of the automated NucliSENS easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for high-throughput monitoring of human immunodeficiency virus load.J Clin Microbiol. 2007 Apr;45(4):1244-9. doi: 10.1128/JCM.01540-06. Epub 2007 Jan 31. J Clin Microbiol. 2007. PMID: 17267632 Free PMC article.
-
Comparison of the Generic HIV Viral Load assay with the Amplicor HIV-1 monitor v1.5 and Nuclisens HIV-1 EasyQ v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: the Kesho Bora preparatory study.J Virol Methods. 2010 Feb;163(2):253-7. doi: 10.1016/j.jviromet.2009.10.005. Epub 2009 Oct 27. J Virol Methods. 2010. PMID: 19837114
-
Quantitative detection of HIV-1 RNA using NucliSens EasyQ HIV-1 assay.J Virol Methods. 2005 Oct;129(1):40-6. doi: 10.1016/j.jviromet.2005.04.017. J Virol Methods. 2005. PMID: 15961170
Cited by
-
Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens.J Clin Microbiol. 2007 Feb;45(2):421-5. doi: 10.1128/JCM.00894-06. Epub 2006 Dec 13. J Clin Microbiol. 2007. PMID: 17166966 Free PMC article.
-
Multicenter performance evaluation of a new TaqMan PCR assay for monitoring human immunodeficiency virus RNA load.J Clin Microbiol. 2006 Dec;44(12):4371-5. doi: 10.1128/JCM.00505-06. Epub 2006 Sep 27. J Clin Microbiol. 2006. PMID: 17005750 Free PMC article.
-
Evaluation of the NucliSens EasyQ v2.0 assay in comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in quantification of C-clade HIV-1 in plasma.PLoS One. 2014 Aug 26;9(8):e103983. doi: 10.1371/journal.pone.0103983. eCollection 2014. PLoS One. 2014. PMID: 25157919 Free PMC article.
-
Performance of three commercial viral load assays, Versant human immunodeficiency virus type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, testing HIV-1 non-B subtypes and recombinant variants.J Clin Microbiol. 2008 Sep;46(9):2918-23. doi: 10.1128/JCM.02414-07. Epub 2008 Jul 2. J Clin Microbiol. 2008. PMID: 18596140 Free PMC article.
-
Role of the laboratory in ensuring global access to ARV treatment for HIV-infected children: consensus statement on the performance of laboratory assays for early infant diagnosis.Open AIDS J. 2008;2:17-25. doi: 10.2174/1874613600802010017. Epub 2008 Mar 10. Open AIDS J. 2008. PMID: 18923696 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical