Imaging of macrophages in soft-tissue infection in rats: relationship between ultrasmall superparamagnetic iron oxide dose and MR signal characteristics
- PMID: 15665219
- DOI: 10.1148/radiol.2343031172
Imaging of macrophages in soft-tissue infection in rats: relationship between ultrasmall superparamagnetic iron oxide dose and MR signal characteristics
Abstract
Purpose: To describe dose-dependent signal intensity (SI) characteristics of experimentally induced soft-tissue abscesses on 1.5-T T1- and T2*-weighted magnetic resonance (MR) images obtained 24 hours after administration of ultrasmall superparamagnetic iron oxide (USPIO) and to describe the relationship between SI and amount of USPIO uptake and macrophage iron content.
Materials and methods: Local institutional review committee on animal care approved the experiments, which were performed according to the guidelines of the National Institutes of Health and the committee on animal research at our institution. Unilateral calf muscle abscesses were induced in 21 rats with an injection of a Staphylococcus aureus suspension. The rats were divided into three groups of seven animals each: low USPIO dose (50 micromol of iron per kilogram of body weight), high USPIO dose (150 micromol Fe/kg), and control (saline solution). All rats were imaged before and 24 hours after USPIO administration at 1.5 T (transverse T1-weighted spin-echo, T2*-weighted fast gradient-echo, and short inversion time inversion-recovery sequences). Images were analyzed quantitatively and qualitatively with regard to SI and signal pattern. Temporal variation of calculated contrast-to-noise ratios was analyzed with the Wilcoxon signed rank test. MR findings were correlated with histopathologic findings, including those of electron microscopy.
Results: Twenty-four hours after USPIO administration in the high-dose group, susceptibility effects were present in abscess periphery on postcontrast T2*-weighted images (P=.04), and SI enhancement was noted on postcontrast T1-weighted images within both abscess wall and abscess center (P=.04 for both). In the low-dose group, SI enhancement was noted in entire abscess on T1-weighted postcontrast images (P=.03). Neither significant SI loss (P=.09) nor susceptibility effects were detected in periphery or center of any abscess on postcontrast T2*-weighted images. There was no obvious difference in total amount of macrophages among the groups, but there was a clear difference with regard to individual iron content of iron-positive macrophages between the USPIO dose groups.
Conclusion: At 1.5 T, SI characteristics of abscesses on T1- and T2*-weighted images obtained 24 hours after USPIO injection strongly depend on administered dose of the contrast agent. At low doses, T1 effects were stronger than T2* effects.
Similar articles
-
MR imaging with ultrasmall superparamagnetic iron oxide particles in experimental soft-tissue infections in rats.Radiology. 2002 Dec;225(3):808-14. doi: 10.1148/radiol.2253011485. Radiology. 2002. PMID: 12461265
-
Detection of synovial macrophages in an experimental rabbit model of antigen-induced arthritis: ultrasmall superparamagnetic iron oxide-enhanced MR imaging.Radiology. 2004 Oct;233(1):149-57. doi: 10.1148/radiol.2331031402. Epub 2004 Aug 27. Radiology. 2004. PMID: 15333767
-
Extra- and intracellular accumulation of ultrasmall superparamagnetic iron oxides (USPIO) in experimentally induced abscesses of the peripheral soft tissues and their effects on magnetic resonance imaging.Magn Reson Imaging. 1999 May;17(4):557-67. doi: 10.1016/s0730-725x(98)00206-9. Magn Reson Imaging. 1999. PMID: 10231182
-
Macrophage imaging in central nervous system and in carotid atherosclerotic plaque using ultrasmall superparamagnetic iron oxide in magnetic resonance imaging.Invest Radiol. 2004 Oct;39(10):619-25. doi: 10.1097/01.rli.0000135980.08491.33. Invest Radiol. 2004. PMID: 15377941 Review.
-
Iron oxide-enhanced MR lymphography: initial experience.Eur J Radiol. 2000 Jun;34(3):257-64. doi: 10.1016/s0720-048x(00)00204-7. Eur J Radiol. 2000. PMID: 10927166 Review.
Cited by
-
Ex vivo magnetic particle imaging of vascular inflammation in abdominal aortic aneurysm in a murine model.Sci Rep. 2020 Jul 24;10(1):12410. doi: 10.1038/s41598-020-69299-y. Sci Rep. 2020. PMID: 32709967 Free PMC article.
-
Development of Bifunctional Gadolinium-Labeled Superparamagnetic Nanoparticles (Gd-MnMEIO) for In Vivo MR Imaging of the Liver in an Animal Model.PLoS One. 2016 Feb 17;11(2):e0148695. doi: 10.1371/journal.pone.0148695. eCollection 2016. PLoS One. 2016. PMID: 26886558 Free PMC article.
-
Certain types of iron oxide nanoparticles are not suited to passively target inflammatory cells that infiltrate the brain in response to stroke.J Cereb Blood Flow Metab. 2013 May;33(5):e1-9. doi: 10.1038/jcbfm.2013.22. Epub 2013 Feb 27. J Cereb Blood Flow Metab. 2013. PMID: 23443176 Free PMC article.
-
The Effect of Inversion Time on the Relationship Between Iron Oxide Nanoparticles Concentration and Signal Intensity in T1-Weighted MR Images.Iran J Radiol. 2014 May;11(2):e12667. doi: 10.5812/iranjradiol.12667. Epub 2014 May 15. Iran J Radiol. 2014. PMID: 25035696 Free PMC article.
-
USPIO-enhanced MRI of highly invasive and highly metastasizing transplanted human squamous cell carcinoma: an experimental study.Dentomaxillofac Radiol. 2012 Jan;41(1):55-63. doi: 10.1259/dmfr/28673011. Epub 2011 Nov 24. Dentomaxillofac Radiol. 2012. PMID: 22116119 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical