Purpose: The advent of sentinel lymph node mapping and biopsy in the staging of breast cancer has resulted in a significant decrease in the extent of axillary nodal surgery. As the extent of axillary surgery decreases, the radiation dose and distribution within the axilla becomes increasingly important for current therapy planning and future analysis of results. This analysis examined the radiation dose distribution delivered to the anatomically defined axillary level I and II lymph node volume and surgically placed axillary clips with conventional tangential breast fields and CT-based three-dimensional (3D) planning.
Methods and materials: Fifty consecutive patients with early-stage breast cancer undergoing breast conservation therapy were evaluated. All patients underwent 3D CT-based planning with conventional breast tangential fields designed to encompass the entire breast parenchyma. Using CT-based 3D planning, the dose distribution of the standard tangential breast irradiation fields was examined in relationship to the axillary level I and II lymph node volumes. Axillary level I and II lymph node anatomic volumes were defined by CT and surgical clips placed during complete level I-II lymph node dissection. Axillary level I-II lymph node volume doses were examined on the basis of the prescribed breast radiation dose and 3D dose distribution.
Results: All defined breast volumes received > or =95% of the prescribed dose. By contrast, the 95% isodose line encompassed only an average of 55% (range, 23-87%) of the axillary level I-II lymph node anatomic volume. No patient had complete coverage of the axillary level I-II lymph node region by the 95% isodose line. The mean anatomic axillary level I-II volume was 146.3 cm(3) (range, 83.1-313.0 cm(3)). The mean anatomic axillary level I-II volume encompassed by the 95% isodose line was 84.9 cm(3) (range, 25.1-219.0 cm(3)). The mean 95% isodose coverage of the surgical clip volume was 80%, and the median value was 81% (range, 58-98%). The mean volume deficit between the axillary level I-II volume and the surgical clip volume was 41.7 cm(3) (median, 30.0 cc).
Conclusion: In this study, standard tangential breast radiation fields failed to deliver a therapeutic dose adequately to the axillary level I-II lymph node anatomic volume. No patient received complete coverage of the axillary level I-II lymph node volume. Surgically placed axillary clips also failed to delineate the level I-II axilla adequately. Definitive irradiation of the level I and II axillary lymph node region requires significant modification of standard tangential fields, best accomplished with 3D treatment planning, with specific targeting of anatomically defined axillary lymph node volumes as described, in addition to the breast parenchymal volumes.
Similar articles
-
Evaluation of novel modified tangential irradiation technique for breast cancer patients using dose-volume histograms.Int J Radiat Oncol Biol Phys. 2004 Mar 15;58(4):1280-8. doi: 10.1016/j.ijrobp.2003.10.010. Int J Radiat Oncol Biol Phys. 2004. PMID: 15001273
-
[Management of the axilla in breast cancer: evidences and unresolved issues].Orv Hetil. 2001 Sep 9;142(36):1941-50. Orv Hetil. 2001. PMID: 11680099 Review. Hungarian.
-
Dose distribution analysis of axillary lymph nodes for three-dimensional conformal radiotherapy with a field-in-field technique for breast cancer.Int J Radiat Oncol Biol Phys. 2009 Jan 1;73(1):80-7. doi: 10.1016/j.ijrobp.2008.04.003. Epub 2008 Jul 3. Int J Radiat Oncol Biol Phys. 2009. PMID: 18602764 Clinical Trial.
-
Irradiation with standard tangential breast fields in patients treated with conservative surgery and sentinel node biopsy: using a three-dimensional tool to evaluate the first level coverage of the axillary nodes.Br J Radiol. 2005 Jan;78(925):51-4. doi: 10.1259/bjr/29242407. Br J Radiol. 2005. PMID: 15673530
-
[Early breast cancer without axillary lymph node involvement].Cancer Radiother. 2010 Nov;14 Suppl 1:S127-35. doi: 10.1016/S1278-3218(10)70016-0. Cancer Radiother. 2010. PMID: 21129655 Review. French.
Cited by
-
Optimal management of sentinel lymph node positive biopsy patients in early breast cancer.Ann Transl Med. 2015 May;3(7):87. doi: 10.3978/j.issn.2305-5839.2015.02.33. Ann Transl Med. 2015. PMID: 26015929 Free PMC article. No abstract available.
-
Breast-conserving surgery followed by whole-breast irradiation offers survival benefits over mastectomy without irradiation.Br J Surg. 2018 Nov;105(12):1607-1614. doi: 10.1002/bjs.10889. Epub 2018 Jun 21. Br J Surg. 2018. PMID: 29926900 Free PMC article.
-
Acute toxicity outcomes and dosimetric implications from incidental irradiation of adjacent tissues in tangent field hypofractionated breast radiotherapy.Rep Pract Oncol Radiother. 2020 May-Jun;25(3):345-350. doi: 10.1016/j.rpor.2020.02.009. Epub 2020 Feb 21. Rep Pract Oncol Radiother. 2020. PMID: 32214909 Free PMC article.
-
Virtual lymph node analysis to evaluate axillary lymph node coverage provided by tangential breast irradiation.Radiat Oncol J. 2015 Mar;33(1):50-6. doi: 10.3857/roj.2015.33.1.50. Epub 2015 Mar 31. Radiat Oncol J. 2015. PMID: 25874178 Free PMC article.
-
Radiation therapy after breast-conserving surgery.Radiat Med. 2006 Jun;24(5):388-404. doi: 10.1007/s11604-005-0021-y. Radiat Med. 2006. PMID: 16958420 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials