Chromatic dispersions of the ocular media of human eyes
- PMID: 15669612
- DOI: 10.1364/josaa.22.000029
Chromatic dispersions of the ocular media of human eyes
Abstract
Of the commonly used chromatic dispersion equations, only the Sellmeier and the Cauchy equations seem to be theoretically based. Cauchy's equation is derived from the Sellmeier equation, is simpler to implement, and was found to give an excellent fit to published refractive-index data of the human eye. We used Cauchy's equation to model the chromatic difference in refraction of the Gullstrand number 1 schematic eye with a gradient-index lens. To estimate the dispersion at different refractive-index levels within the lens, a single dispersion equation at one nominal refractive index was linearly scaled. This scaling was justified after exploring the effect of mean refractive index on dispersion by using Sellmeier's equation and finding that a dispersion equation for one wavelength is just a linearly scaled version of the dispersion equation at any other wavlength. Because Cauchy's equation is theoretically based and gives excellent fit to data in the visible spectrum, it can be used to extrapolate results into the near infrared with confidence.
Similar articles
-
Adjusting a light dispersion model to fit measurements from vertebrate ocular media as well as ray-tracing in fish lenses.Vision Res. 2010 Apr 21;50(9):850-3. doi: 10.1016/j.visres.2010.02.020. Epub 2010 Feb 26. Vision Res. 2010. PMID: 20219517
-
A schematic eye for the mouse, and comparisons with the rat.Vision Res. 1985;25(1):21-31. doi: 10.1016/0042-6989(85)90076-8. Vision Res. 1985. PMID: 3984214
-
Longitudinal chromatic aberration of the human infant eye.J Opt Soc Am A Opt Image Sci Vis. 2008 Sep;25(9):2263-70. doi: 10.1364/josaa.25.002263. J Opt Soc Am A Opt Image Sci Vis. 2008. PMID: 18758552 Free PMC article.
-
Optical models of the human eye.Clin Exp Optom. 2016 Mar;99(2):99-106. doi: 10.1111/cxo.12352. Epub 2016 Mar 10. Clin Exp Optom. 2016. PMID: 26969304 Review.
-
Optical plasticity in fish lenses.Prog Retin Eye Res. 2013 May;34:78-88. doi: 10.1016/j.preteyeres.2012.12.001. Epub 2012 Dec 20. Prog Retin Eye Res. 2013. PMID: 23262260 Review.
Cited by
-
Chromatic cues for the sign of defocus in the peripheral retina.Biomed Opt Express. 2024 Aug 8;15(9):5098-5114. doi: 10.1364/BOE.537268. eCollection 2024 Sep 1. Biomed Opt Express. 2024. PMID: 39296412 Free PMC article.
-
Tear film measurement by optical reflectometry technique.J Biomed Opt. 2014 Feb;19(2):027001. doi: 10.1117/1.JBO.19.2.027001. J Biomed Opt. 2014. PMID: 24500519 Free PMC article.
-
Assessment of eye length changes in accommodation using dynamic extended-depth OCT.Biomed Opt Express. 2017 Apr 26;8(5):2709-2719. doi: 10.1364/BOE.8.002709. eCollection 2017 May 1. Biomed Opt Express. 2017. PMID: 28663900 Free PMC article.
-
Quantification of age-related and per diopter accommodative changes of the lens and ciliary muscle in the emmetropic human eye.Invest Ophthalmol Vis Sci. 2013 Feb 7;54(2):1095-105. doi: 10.1167/iovs.12-10619. Invest Ophthalmol Vis Sci. 2013. PMID: 23287789 Free PMC article.
-
Geometry-invariant GRIN lens: iso-dispersive contours.Biomed Opt Express. 2012 Jul 1;3(7):1684-700. doi: 10.1364/BOE.3.001684. Epub 2012 Jun 22. Biomed Opt Express. 2012. PMID: 22808438 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources