The influence of a manual glide path on the separation rate of NiTi rotary instruments
- PMID: 15671822
- DOI: 10.1097/01.don.0000136209.28647.13
The influence of a manual glide path on the separation rate of NiTi rotary instruments
Abstract
The dual purpose of this study was, to evaluate the fracture rate of Ni-Ti rotary instruments when following a manual glide path and using stainless steel hand files before carrying out instrumentation by means of rotary files and, to compare the results in this study with those obtained in two previous analyses, in which the glide path technique was not used. A total of 208 canals obtained from a pool of freshly extracted human mandibular and maxillary molars was divided into three groups corresponding to; K3, ProFile and ProTaper. The coronal 2/3 of each tooth were used. In all three groups the apical portion of the samples was prepared with size 10-20 stainless steel K-type hand files. The apical stops were prepared using K3, ProFile and ProTaper rotary instruments. Logistic regression model analysis indicated that breakage was significantly associated with the angle of curvature of the canal (OR = 1.078; 95% CI = 1.032-1.12; p = 0.001), and with the number of clinical uses (files used more than eight times broke more frequently that those used 1 or 2 times; OR: 22.686; 95% CI: 2.6-191.3; p = 0.004). The breakage rate obtained in the present study is significantly lower than in our previous studies, in which the angle of curvature was also greater than 30 degrees and rotational speed a constant 350 rpm, but in which the canals were not first prepared with hand files (25/205 = 12% versus 16/61 = 26%, p = 0.007). Based on the results of this study, we recommend the use of stainless steel hand files to prepare the apical 1/3 of curved canals before introducing rotary files.
Similar articles
-
Evaluation of a new nickel-titanium system to create the glide path in root canal preparation of curved canals.J Endod. 2013 Dec;39(12):1581-4. doi: 10.1016/j.joen.2013.06.037. Epub 2013 Oct 13. J Endod. 2013. PMID: 24238451
-
Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth.Int Endod J. 2003 Mar;36(3):208-17. doi: 10.1046/j.1365-2591.2003.00644.x. Int Endod J. 2003. PMID: 12657147
-
Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation.Int Endod J. 2005 Oct;38(10):743-52. doi: 10.1111/j.1365-2591.2005.01010.x. Int Endod J. 2005. PMID: 16164689
-
In Vivo and In Vitro Effectiveness of Rotary Nickel-Titanium vs Manual Stainless Steel Instruments for Root Canal Therapy: Systematic Review and Meta-analysis.J Evid Based Dent Pract. 2018 Mar;18(1):59-69. doi: 10.1016/j.jebdp.2017.08.001. Epub 2017 Aug 19. J Evid Based Dent Pract. 2018. PMID: 29478682
-
The Effect of Glide Path Preparation on Root Canal Shaping Procedures and Outcomes.Eur Endod J. 2022 Jun;7(2):92-105. doi: 10.14744/eej.2022.97659. Eur Endod J. 2022. PMID: 35786583 Free PMC article. Review.
Cited by
-
Comparison of the Shaping Ability of WaveOne Reciprocating Files with or without Glide Path in Simulated Curved S-shaped Root Canals.J Int Soc Prev Community Dent. 2017 Jun;7(Suppl 1):S13-S17. doi: 10.4103/jispcd.JISPCD_32_17. Epub 2017 Jun 20. J Int Soc Prev Community Dent. 2017. PMID: 28713762 Free PMC article.
-
Modifications in Canal Anatomy of Curved Canals of Mandibular First Molars by two Glide Path Instruments using CBCT.J Clin Diagn Res. 2014 Nov;8(11):ZC13-7. doi: 10.7860/JCDR/2014/8702.5101. Epub 2014 Nov 20. J Clin Diagn Res. 2014. PMID: 25584304 Free PMC article.
-
Modalities of using endodontic nickel-titanium rotary instruments and factors influencing their implementation in dental practice.BMC Oral Health. 2018 Nov 21;18(1):192. doi: 10.1186/s12903-018-0660-x. BMC Oral Health. 2018. PMID: 30463557 Free PMC article.
-
Endodontic Rotary Files, What Should an Endodontist Know?Medicina (Kaunas). 2022 May 27;58(6):719. doi: 10.3390/medicina58060719. Medicina (Kaunas). 2022. PMID: 35743982 Free PMC article. Review.
-
Cyclic fatigue resistance of R-Pilot, WaveOne Gold Glider, and ProGlider glide path instruments.Clin Oral Investig. 2018 Dec;22(9):3007-3012. doi: 10.1007/s00784-018-2391-4. Epub 2018 Feb 17. Clin Oral Investig. 2018. PMID: 29455371
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources