Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2005 Feb;100(2):580-584.
doi: 10.1213/01.ANE.0000143339.40385.1B.

Positive end-expiratory pressure during induction of general anesthesia increases duration of nonhypoxic apnea in morbidly obese patients

Affiliations
Clinical Trial

Positive end-expiratory pressure during induction of general anesthesia increases duration of nonhypoxic apnea in morbidly obese patients

Sylvain Gander et al. Anesth Analg. 2005 Feb.

Abstract

Positive end-expiratory pressure (PEEP) applied during induction of anesthesia prevents atelectasis formation and increases the duration of nonhypoxic apnea in nonobese patients. PEEP also prevents atelectasis formation in morbidly obese patients. Because morbidly obese patients have difficult airway management more often and because arterial desaturation develops rapidly, we studied the clinical benefit of PEEP applied during anesthesia induction. Thirty morbidly obese patients were randomly allocated to one of two groups. In the PEEP group, patients breathed 100% O(2) through a continuous positive airway pressure device (10 cm H(2)O) for 5 min. After induction of anesthesia, they were mechanically ventilated with PEEP (10 cm H(2)O) for another 5 min until tracheal intubation. In the control group, the sequence was the same but without any continuous positive airway pressure or PEEP. We measured apnea duration until Spo(2) reached 90% and we performed arterial blood gases analyses just before apnea and at 92% Spo(2). Nonhypoxic apnea duration was longer in the PEEP group compared with the control group (188 +/- 46 versus 127 +/- 43 s; P = 0.002). Pao(2) was higher before apnea in the PEEP group (P = 0.038). Application of positive airway pressure during induction of general anesthesia in morbidly obese patients increases nonhypoxic apnea duration by 50%.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Marshall BE, Wyche MQ. Hypoxemia during and after anesthesia. Anesthesiology 1972;37:178–209.
    1. Moller JT, Johannessen NW, Berg H, et al. Hypoxaemia during anaesthesia: an observer study. Br J Anaesth 1991;66:437–44.
    1. Hedenstierna G, Tokics L, Strandberg A, et al. Correlation of gas exchange impairment to development of atelectasis during anaesthesia and muscle paralysis. Acta Anaesthesiol Scand 1986;30:183–91.
    1. Magnusson L, Spahn DR. New concepts of atelectasis during general anaesthesia. Br J Anaesth 2003;91:61–72.
    1. Neumann P, Rothen HU, Berglund JE, et al. Positive end-expiratory pressure prevents atelectasis during general anaesthesia even in the presence of a high inspired oxygen concentration. Acta Anaesthesiol Scand 1999;43:295–301.

Publication types

LinkOut - more resources