Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries
- PMID: 15678319
- DOI: 10.1007/s00330-005-2677-1
Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries
Abstract
The aims of this study were (1) to assess the diagnostic performance of multidetector row computed tomography angiography (CTA) on imaging of renal artery branches and (2) to investigate the effect of different iodine concentrations at constant total iodine load and either constant injection rates or constant iodine administration rates. A number of 120 consecutive patients (71+/-6 years of age) underwent CTA of renal arteries (collimation 4 x 1 mm) using the nonionic contrast medium iopromide, and were divided into six equal groups: 1: 150 ml, 240 mg/ml at 4 ml/s; 2: 120 ml, 300 mg/ml at 4 ml/s; 3: 97.3 ml, 370 mg/ml at 4 ml/s; 4: 150 ml, 240 mg/ml at 5 ml/s; 5: 120 ml, 300 mg/ml, 60 ml at 6 ml/s, 60 ml at 3 ml/s; 6: 97.3 ml, 370 mg/ml at 3.3 ml/s. The image quality of the main renal arteries (n=240) and their first-order to fourth-order branches was scored as 0 for no visualization, 1 for only visualization, and 2 for diagnostic. All main renal arteries were diagnostic. First-order branches had score 2 in 38/40, 40/40, 37/40, 38/40, 39/40, and 40/40 patients for groups 1-6, respectively (p=0.34). Second-order branches were imaged best in group 2 (p<0.002)). Third-order branches had score 2 in only 1/40, 5/40, 1/40, 2/40, 0/40, and 2/40 renal arteries. Fourth-order branches were not imaged diagnostically. At a constant total iodine load, the main renal arteries and their first-order branches achieved diagnostic image quality at all iodine concentrations in four-channel multidetector row CTA for the protocols tested. Second-order renal artery branches were imaged best at 120 ml contrast medium with an iodine concentration of 300 mg/ml at 4 ml/s.
Similar articles
-
A prospective study comparing different iodine concentrations for triphasic multidetector row CT of the upper abdomen.Eur J Radiol. 2006 Oct;60(1):95-9. doi: 10.1016/j.ejrad.2006.05.012. Epub 2006 Aug 1. Eur J Radiol. 2006. PMID: 16879942 Clinical Trial.
-
Evaluation of renal artery in hypertensive patients by unenhanced MR angiography using spatial labeling with multiple inversion pulses sequence and by CT angiography.AJR Am J Roentgenol. 2012 Nov;199(5):1142-8. doi: 10.2214/AJR.11.7263. AJR Am J Roentgenol. 2012. PMID: 23096191
-
Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients.Eur J Radiol. 2016 Jun;85(6):1068-74. doi: 10.1016/j.ejrad.2016.03.022. Epub 2016 Mar 22. Eur J Radiol. 2016. PMID: 27161054
-
MDCT of renal and mesenteric vessels.Eur Radiol. 2003 Dec;13 Suppl 5:M94-101. doi: 10.1007/s00330-003-2103-5. Eur Radiol. 2003. PMID: 14989617 Review.
-
Multiple detector-row CT angiography of the renal and mesenteric vessels.Eur J Radiol. 2003 Mar;45 Suppl 1:S79-87. doi: 10.1016/s0720-048x(02)00364-9. Eur J Radiol. 2003. PMID: 12598031 Review.
Cited by
-
Imaging quality evaluation of low tube voltage coronary CT angiography using low concentration contrast medium.PLoS One. 2015 Mar 26;10(3):e0120539. doi: 10.1371/journal.pone.0120539. eCollection 2015. PLoS One. 2015. PMID: 25811785 Free PMC article.
-
A comparison of the use of contrast media with different iodine concentrations for multidetector CT of the kidney.Korean J Radiol. 2011 Nov-Dec;12(6):714-21. doi: 10.3348/kjr.2011.12.6.714. Epub 2011 Sep 27. Korean J Radiol. 2011. PMID: 22043154 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical