Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Jun;15(6):1211-4.
doi: 10.1007/s00330-005-2677-1. Epub 2005 Jan 28.

Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries

Affiliations
Comparative Study

Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries

Joern J W Sandstede et al. Eur Radiol. 2005 Jun.

Abstract

The aims of this study were (1) to assess the diagnostic performance of multidetector row computed tomography angiography (CTA) on imaging of renal artery branches and (2) to investigate the effect of different iodine concentrations at constant total iodine load and either constant injection rates or constant iodine administration rates. A number of 120 consecutive patients (71+/-6 years of age) underwent CTA of renal arteries (collimation 4 x 1 mm) using the nonionic contrast medium iopromide, and were divided into six equal groups: 1: 150 ml, 240 mg/ml at 4 ml/s; 2: 120 ml, 300 mg/ml at 4 ml/s; 3: 97.3 ml, 370 mg/ml at 4 ml/s; 4: 150 ml, 240 mg/ml at 5 ml/s; 5: 120 ml, 300 mg/ml, 60 ml at 6 ml/s, 60 ml at 3 ml/s; 6: 97.3 ml, 370 mg/ml at 3.3 ml/s. The image quality of the main renal arteries (n=240) and their first-order to fourth-order branches was scored as 0 for no visualization, 1 for only visualization, and 2 for diagnostic. All main renal arteries were diagnostic. First-order branches had score 2 in 38/40, 40/40, 37/40, 38/40, 39/40, and 40/40 patients for groups 1-6, respectively (p=0.34). Second-order branches were imaged best in group 2 (p<0.002)). Third-order branches had score 2 in only 1/40, 5/40, 1/40, 2/40, 0/40, and 2/40 renal arteries. Fourth-order branches were not imaged diagnostically. At a constant total iodine load, the main renal arteries and their first-order branches achieved diagnostic image quality at all iodine concentrations in four-channel multidetector row CTA for the protocols tested. Second-order renal artery branches were imaged best at 120 ml contrast medium with an iodine concentration of 300 mg/ml at 4 ml/s.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Rofo. 1994 Dec;161(6):519-25 - PubMed
    1. Eur Radiol. 2001;11(8):1396-400 - PubMed
    1. Eur Radiol. 1999;9(3):546-51 - PubMed
    1. Invest Radiol. 2003 Nov;38(11):690-4 - PubMed
    1. Eur Radiol. 2003 Dec;13 Suppl 5:M94-101 - PubMed

Publication types