Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2005 Feb;79(2):485-90; discussion 490-1.
doi: 10.1016/j.athoracsur.2004.06.120.

Video and robotic-assisted minimally invasive mitral valve surgery: a comparison of the Port-Access and transthoracic clamp techniques

Affiliations
Clinical Trial

Video and robotic-assisted minimally invasive mitral valve surgery: a comparison of the Port-Access and transthoracic clamp techniques

Hermann Reichenspurner et al. Ann Thorac Surg. 2005 Feb.

Abstract

Background: In order to assess different surgical techniques for video-assisted minimally invasive mitral valve surgery, a retrospective study was undertaken comparing the Port-Access system (Cardiovations, Ethicon Inc, Somerville, NJ) and the transthoracic clamp technique.

Methods: In 120 patients mitral valve surgery was performed through a small right minithoracotomy using either the Port-Access endovascular cardiopulmonary bypass system (Port-Access, n = 60) or the transthoracic clamp technique (MICRO, n = 60). Mean patient age was 61.5 +/- 10.5 years (81 patients with isolated mitral valve insufficiency, 39 patients with combined mitral valve disease).

Results: Eighty-one (67.5%) patients underwent mitral valve repair and 39 (32.5%) patients had valve replacement. Mean time of surgery was 4.5 +/- 3.5 and 4.1 +/- 3.2 hours (p = 0.07), aortic cross-clamp time 89 +/- 69 and 78 +/- 65 minutes (p = 0.08), mean intensive care unit stay 1.5 +/- 2.1 and 1.6 +/- 2.5 days (p = ns), and hospital stay 9.0 +/- 10.5 and 9.2 +/- 9.7 days (p = ns) in the Port-Access and MICRO groups, respectively. In the Port-Access group, there were 6 reexplorations for bleeding, one perforation of the right ventricle with the endopulmonary vent, and 2 reconstructions of the femoral artery necessary after femoral cannulation, compared to one reexploration for bleeding in the MICRO group. There was only one minor paravalvular leak after replacement and 2 cases of residual greater than or equal to grade II mitral valve regurgitation after mitral valve repair in the Port-Access group, necessitating reoperation. In both groups, there was no mortality, no cerebrovascular accident, no aortic dissection, and no conversion to sternotomy.

Conclusions: Minimally invasive mitral valve surgery has become a standard approach for isolated mitral valve operations at our institution. The MICRO technique tends to shorten the time of surgery and aortic cross-clamping and reduces perioperative costs by simplifying the operative procedure.

PubMed Disclaimer

LinkOut - more resources