Simultaneous determination of pH, urea, acetylcholine and heavy metals using array-based enzymatic optical biosensor
- PMID: 15681196
- DOI: 10.1016/j.bios.2004.07.008
Simultaneous determination of pH, urea, acetylcholine and heavy metals using array-based enzymatic optical biosensor
Abstract
An array-based optical biosensor for the simultaneous analysis of multiple samples in the presence of unrelated multi-analytes was fabricated. Urease and acetylcholinesterase (AChE) were used as model enzymes and were co-entrapped with the sensing probe, FITC-dextran, in the sol-gel matrix to measure pH, urea, acetylcholine (ACh) and heavy metals (enzyme inhibitors). Environmental and biological samples spiked with metal ions were also used to evaluate the application of the array biosensor to real samples. The biosensor exhibited high specificity in identifying multiple analytes. No obvious cross-interference was observed when a 50-spot array biosensor was used for simultaneous analysis of multiple samples in the presence of multiple analytes. The sensing system can determine pH over a dynamic range from 4 to 8.5. The limits of detection (LODs) of 2.5-50 microM with a dynamic range of 2-3 orders of magnitude for urea and ACh measurements were obtained. Moreover, the urease-encapsulated array biosensor was used to detect heavy metals. The analytical ranges of Cd(II), Cu(II), and Hg(II) were between 10 nM and 100 mM. When real samples were spiked with heavy metals, the array biosensor also exhibited potential effectiveness in screening enzyme inhibitors.
Similar articles
-
Simultaneous determination of biomarkers for Alzheimer's disease using sol-gel-derived optical array biosensor.Biosens Bioelectron. 2010 Jul 15;25(11):2464-9. doi: 10.1016/j.bios.2010.04.005. Epub 2010 Apr 14. Biosens Bioelectron. 2010. PMID: 20444591
-
Array-based titanium dioxide biosensors for ratiometric determination of glucose, glutamate and urea.Biosens Bioelectron. 2010 Feb 15;25(6):1439-46. doi: 10.1016/j.bios.2009.10.044. Epub 2009 Nov 6. Biosens Bioelectron. 2010. PMID: 19954963
-
Simultaneous determination of renal clinical analytes in serum using hydrolase- and oxidase-encapsulated optical array biosensors.Anal Biochem. 2004 Nov 1;334(1):183-92. doi: 10.1016/j.ab.2004.08.009. Anal Biochem. 2004. PMID: 15464967
-
Electrochemical biosensor technology: application to pesticide detection.Methods Mol Biol. 2009;504:115-26. doi: 10.1007/978-1-60327-569-9_8. Methods Mol Biol. 2009. PMID: 19159094 Review.
-
Enzyme inhibition-based biosensors for food safety and environmental monitoring.Biosens Bioelectron. 2006 Feb 15;21(8):1405-23. doi: 10.1016/j.bios.2005.07.012. Epub 2005 Aug 25. Biosens Bioelectron. 2006. PMID: 16125923 Review.
Cited by
-
Ultrasonic atomizer based development of pH sensor for real time analysis.Sci Rep. 2020 Jul 2;10(1):10910. doi: 10.1038/s41598-020-68005-2. Sci Rep. 2020. PMID: 32616901 Free PMC article.
-
Highly Bright Gold Nanowires Arrays for Sensitive Detection of Urea and Urease.Nanomaterials (Basel). 2022 Nov 16;12(22):4023. doi: 10.3390/nano12224023. Nanomaterials (Basel). 2022. PMID: 36432310 Free PMC article.
-
Bio-Recognition in Spectroscopy-Based Biosensors for *Heavy Metals-Water and Waterborne Contamination Analysis.Biosensors (Basel). 2019 Jul 30;9(3):96. doi: 10.3390/bios9030096. Biosensors (Basel). 2019. PMID: 31366137 Free PMC article. Review.
-
Efficient Portable Urea Biosensor Based on Urease Immobilized Membrane for Monitoring of Physiological Fluids.Biomedicines. 2020 Dec 11;8(12):596. doi: 10.3390/biomedicines8120596. Biomedicines. 2020. PMID: 33322630 Free PMC article.
-
pH and Urea Estimation in Urine Samples using Single Fluorophore and Ratiometric Fluorescent Biosensors.Sci Rep. 2017 Jul 19;7(1):5840. doi: 10.1038/s41598-017-06060-y. Sci Rep. 2017. PMID: 28724984 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources