Automated quantification of myocardial perfusion SPECT using simplified normal limits

Affiliations
Clinical Trial

Automated quantification of myocardial perfusion SPECT using simplified normal limits

Piotr J Slomka et al. J Nucl Cardiol. 2005 Jan-Feb.

Abstract

Background: To simplify development of normal limits for myocardial perfusion SPECT (MPS), we implemented a quantification scheme in which normal limits are derived without visual scoring of abnormal scans or optimization of regional thresholds.

Methods and results: Normal limits were derived from same-day TI-201 rest/Tc-99m-sestamibi stress scans of male (n = 40) and female (n = 40) low-likelihood patients. Defect extent, total perfusion deficit (TPD), and regional perfusion extents were derived by comparison to normal limits in polar-map coordinates. MPS scans from 256 consecutive patients without known coronary artery disease, who underwent coronary angiography, were analyzed. The new method of quantification (TPD) was compared with our previously developed quantification system and visual scoring. The receiver operator characteristic area under the curve for detection of 50% or greater stenoses by TPD (0.88 +/- 0.02) was higher than by visual scoring (0.83 +/- 0.03) ( P = .039) or standard quantification (0.82 +/- 0.03) ( P = .004). For detection of 70% or greater stenoses, it was higher for TPD (0.89 +/- 0.02) than for standard quantification (0.85 +/- 0.02) ( P = .014). Sensitivity and specificity were 93% and 79%, respectively, for TPD; 81% and 85%, respectively, for visual scoring; and 80% and 73%, respectively, for standard quantification. The use of stress mode-specific normal limits did not improve performance.

Conclusion: Simplified quantification achieves performance better than or equivalent to visual scoring or quantification based on per-segment visual optimization of abnormality thresholds.

PubMed Disclaimer

Comment in

  • One good turn deserves another.
    Nichols KJ, Akinboboye OO. Nichols KJ, et al. J Nucl Cardiol. 2005 Jan-Feb;12(1):3-4. doi: 10.1016/j.nuclcard.2004.11.001. J Nucl Cardiol. 2005. PMID: 15682358 No abstract available.

References

    1. Radiology. 1983 Sep;148(3):839-43 - PubMed
    1. Stat Med. 1998 Apr 30;17(8):857-72 - PubMed
    1. J Nucl Cardiol. 1999 Mar-Apr;6(2):177-82 - PubMed
    1. J Nucl Med. 1994 Apr;35(4):609-18 - PubMed
    1. J Am Coll Cardiol. 1993 Nov 1;22(5):1455-64 - PubMed

Publication types

LinkOut - more resources