Parametric vs. non-parametric statistics of low resolution electromagnetic tomography (LORETA)
- PMID: 15683191
- DOI: 10.1177/155005940503600103
Parametric vs. non-parametric statistics of low resolution electromagnetic tomography (LORETA)
Abstract
This study compared the relative statistical sensitivity of non-parametric and parametric statistics of 3-dimensional current sources as estimated by the EEG inverse solution Low Resolution Electromagnetic Tomography (LORETA). One would expect approximately 5% false positives (classification of a normal as abnormal) at the P < .025 level of probability (two tailed test) and approximately 1% false positives at the P < .005 level. EEG digital samples (2 second intervals sampled 128 Hz, 1 to 2 minutes eyes closed) from 43 normal adult subjects were imported into the Key Institute's LORETA program. We then used the Key Institute's cross-spectrum and the Key Institute's LORETA output files (*.lor) as the 2,394 gray matter pixel representation of 3-dimensional currents at different frequencies. The mean and standard deviation *.lor files were computed for each of the 2,394 gray matter pixels for each of the 43 subjects. Tests of Gaussianity and different transforms were computed in order to best approximate a normal distribution for each frequency and gray matter pixel. The relative sensitivity of parametric vs. non-parametric statistics were compared using a "leave-one-out" cross validation method in which individual normal subjects were withdrawn and then statistically classified as being either normal or abnormal based on the remaining subjects. Log10 transforms approximated Gaussian distribution in the range of 95% to 99% accuracy. Parametric Z score tests at P < .05 cross-validation demonstrated an average misclassification rate of approximately 4.25%, and range over the 2,394 gray matter pixels was 27.66% to 0.11%. At P < .01 parametric Z score cross-validation false positives were 0.26% and ranged from 6.65% to 0% false positives. The non-parametric Key Institute's t-max statistic at P < .05 had an average misclassification error rate of 7.64% and ranged from 43.37% to 0.04% false positives. The nonparametric t-max at P < .01 had an average misclassification rate of 6.67% and ranged from 41.34% to 0% false positives of the 2,394 gray matter pixels for any cross-validated normal subject. In conclusion, adequate approximation to Gaussian distribution and high cross-validation can be achieved by the Key Institute's LORETA programs by using a log10 transform and parametric statistics, and parametric normative comparisons had lower false positive rates than the non-parametric tests.
Similar articles
-
Evaluation and validity of a LORETA normative EEG database.Clin EEG Neurosci. 2005 Apr;36(2):116-22. doi: 10.1177/155005940503600211. Clin EEG Neurosci. 2005. PMID: 15999907 Clinical Trial.
-
Spatial-temporal current source correlations and cortical connectivity.Clin EEG Neurosci. 2007 Jan;38(1):35-48. doi: 10.1177/155005940703800109. Clin EEG Neurosci. 2007. PMID: 17319590
-
Three-dimensional localization of abnormal EEG activity in migraine: a low resolution electromagnetic tomography (LORETA) study of migraine patients in the pain-free interval.Brain Topogr. 2008 Sep;21(1):36-42. doi: 10.1007/s10548-008-0061-6. Epub 2008 Aug 5. Brain Topogr. 2008. PMID: 18679787
-
Functional imaging with low-resolution brain electromagnetic tomography (LORETA): a review.Methods Find Exp Clin Pharmacol. 2002;24 Suppl C:91-5. Methods Find Exp Clin Pharmacol. 2002. PMID: 12575492 Review.
-
[EEG source localization using LORETA (low resolution electromagnetic tomography)].Ideggyogy Sz. 2011 Mar 30;64(3-4):110-8. Ideggyogy Sz. 2011. PMID: 21545008 Review. Hungarian.
Cited by
-
Changes in background electroencephalographic activity in benign childhood epilepsy with centrotemporal spikes after oxcarbazepine treatment: a standardized low-resolution brain electromagnetic tomography (sLORETA) study.BMC Neurol. 2019 Jan 3;19(1):3. doi: 10.1186/s12883-018-1228-8. BMC Neurol. 2019. PMID: 30606133 Free PMC article.
-
Open Eyes Increase Neural Oscillation and Enhance Effective Brain Connectivity of the Default Mode Network: Resting-State Electroencephalogram Research.Front Neurosci. 2022 Apr 27;16:861247. doi: 10.3389/fnins.2022.861247. eCollection 2022. Front Neurosci. 2022. PMID: 35573310 Free PMC article.
-
Variability and effect sizes of intracranial current source density estimations during pain: Systematic review, experimental findings, and future perspectives.Hum Brain Mapp. 2021 Jun 1;42(8):2461-2476. doi: 10.1002/hbm.25380. Epub 2021 Feb 19. Hum Brain Mapp. 2021. PMID: 33605512 Free PMC article.
-
Neurophysiological evidence that musical training influences the recruitment of right hemispheric homologues for speech perception.Front Psychol. 2014 Mar 3;5:171. doi: 10.3389/fpsyg.2014.00171. eCollection 2014. Front Psychol. 2014. PMID: 24624107 Free PMC article.
-
The Learning Curve in neurofeedback of Peter Van Deusen: A review article.Dement Neuropsychol. 2016 Apr-Jun;10(2):98-103. doi: 10.1590/S1980-5764-2016DN1002005. Dement Neuropsychol. 2016. PMID: 29213440 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical