Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Feb;128(2):343-50.
doi: 10.1053/j.gastro.2004.11.018.

Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C

Affiliations
Comparative Study

Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C

Laurent Castéra et al. Gastroenterology. 2005 Feb.

Abstract

Background and aims: Transient elastography (FibroScan; Echosens, Paris, France) is a novel, noninvasive, and rapid bedside method to assess liver fibrosis by measuring liver stiffness. We prospectively assessed the performance of FibroScan in patients with chronic hepatitis C, in comparison with and combined with currently available biochemical markers (Fibrotest; Biopredictive; and the aspartate transaminase to platelets ratio index [APRI]); a liver biopsy examination performed the same day served as the reference.

Methods: We studied 183 consecutive patients with chronic hepatitis C (METAVIR fibrosis stage F1, n = 47; F2, n = 53; F3, n = 37; F4, n = 46).

Results: FibroScan values ranged from 2.4 to 75.4 kilopascals (median, 7.4 kilopascals). Cut-off values were 7.1 kPa for F > or = 2, 9.5 kPa for F > or = 3, and 12.5 kPa for F = 4. The areas under the receiver operating characteristic (ROC) curve of FibroScan, FibroTest, and APRI values were of the same order (.83, .85, and .78, respectively, for F > or = 2; .90, .90, and .84, respectively, for F > or = 3; and .95, .87, and .83, respectively, for F = 4). The best performance was obtained by combining the FibroScan and FibroTest, with areas under the ROC curve of .88 for F > or = 2, .95 for F > or = 3, and .95 for F = 4. When the FibroScan and FibroTest results agreed, liver biopsy examination confirmed them in 84% of cases for F > or = 2, in 95% for F > or = 3, and in 94% for F = 4.

Conclusions: FibroScan is a simple and effective method for assessing liver fibrosis, with similar performance to FibroTest and APRI. The combined use of FibroScan and FibroTest to evaluate liver fibrosis could avoid a biopsy procedure in most patients with chronic hepatitis C.