A sensitive immunoassay based on electropolymerized films by capacitance measurements for direct detection of immunospecies
- PMID: 15691511
- DOI: 10.1016/j.ab.2004.10.051
A sensitive immunoassay based on electropolymerized films by capacitance measurements for direct detection of immunospecies
Abstract
Fabrication of a capacitive immunosensor based on electropolymerized polytyramine (Pty) film for the direct detection of human serum albumin (HSA) without any labeling is described. The capacitance change of the heterostructures, Pty films/covalently bonded antibodies/buffered medium, is utilized for monitoring the specific antibody-antigen interaction. The Pty films are ultrathin and the HSA assay is nearly specific. Experimental parameters affecting antibody immobilization and the sensing of HSA are investigated in detail and optimized. This capacitive sensor prepared with the present method can provide high sensitivity. Under the optimized experimental conditions, a linear calibration curve in the concentration range 1.84-368.6 ng/ml when plotted vs the logarithm of the antigen concentration is obtained and the detection limit (S/N=3) is 1.60 ng/ml. After an acidic washing the present system can be used again. The applicability and reliability of the sensor are also demonstrated.
Similar articles
-
Development of an impedimetric immunosensor based on electropolymerized polytyramine films for the direct detection of Salmonella typhimurium in pure cultures of type strains and inoculated real samples.Anal Chim Acta. 2008 Aug 29;624(2):301-7. doi: 10.1016/j.aca.2008.06.043. Epub 2008 Jul 4. Anal Chim Acta. 2008. PMID: 18706337
-
Highly sensitive electrochemical detection of immunospecies based on combination of Fc label and PPD film/gold nanoparticle amplification.Biosens Bioelectron. 2008 Sep 15;24(1):129-35. doi: 10.1016/j.bios.2008.03.017. Epub 2008 Mar 26. Biosens Bioelectron. 2008. PMID: 18455918
-
A reusable capacitive immunosensor for detection of Salmonella spp. based on grafted ethylene diamine and self-assembled gold nanoparticle monolayers.Anal Chim Acta. 2009 Aug 11;647(2):159-66. doi: 10.1016/j.aca.2009.06.008. Epub 2009 Jun 9. Anal Chim Acta. 2009. PMID: 19591700
-
Nanostructured conducting polymer based reagentless capacitive immunosensor.Biomed Microdevices. 2010 Feb;12(1):63-70. doi: 10.1007/s10544-009-9360-2. Biomed Microdevices. 2010. PMID: 19795211
-
Automated real-time immunoassay of biomolecules.Nature. 1992 Aug 13;358(6387):603-4. doi: 10.1038/358603a0. Nature. 1992. PMID: 1501716 Review.
Cited by
-
Label-free technologies for quantitative multiparameter biological analysis.Anal Bioanal Chem. 2009 May;394(1):121-35. doi: 10.1007/s00216-009-2637-8. Epub 2009 Feb 17. Anal Bioanal Chem. 2009. PMID: 19221722 Free PMC article. Review.
-
Virus-Enabled Biosensor for Human Serum Albumin.Anal Chem. 2017 Jan 17;89(2):1373-1381. doi: 10.1021/acs.analchem.6b04840. Epub 2017 Jan 3. Anal Chem. 2017. PMID: 27989106 Free PMC article.
-
Preparation and characterization of Fe3O4@Au-C225 composite targeted nanoparticles for MRI of human glioma.PLoS One. 2018 Apr 13;13(4):e0195703. doi: 10.1371/journal.pone.0195703. eCollection 2018. PLoS One. 2018. PMID: 29652919 Free PMC article.
-
Design and Preparation of Sensing Surfaces for Capacitive Biodetection.Biosensors (Basel). 2022 Dec 23;13(1):17. doi: 10.3390/bios13010017. Biosensors (Basel). 2022. PMID: 36671852 Free PMC article. Review.
-
Label-Free Impedance Biosensors: Opportunities and Challenges.Electroanalysis. 2007 May 16;19(12):1239-1257. doi: 10.1002/elan.200603855. Electroanalysis. 2007. PMID: 18176631 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources