Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Mar;36(3):676-8.
doi: 10.1161/01.STR.0000155743.60019.e5. Epub 2005 Feb 3.

Magnetic resonance perfusion tracks 133Xe cerebral blood flow changes after carotid stenting

Affiliations
Comparative Study

Magnetic resonance perfusion tracks 133Xe cerebral blood flow changes after carotid stenting

Nerissa U Ko et al. Stroke. 2005 Mar.

Abstract

Background and purpose: To compare magnetic resonance (MR) perfusion to gold-standard cerebral blood flow (CBF) determined by intra-arterial (133)Xe washout method.

Methods: Eight patients with high-grade carotid stenoses underwent bolus-tracking MR perfusion and intra-arterial (133)Xe washout before and after carotid stenting. MR perfusion was compared with 133Xe-CBF values using Pearson linear correlation analysis.

Results: We observed a mean 37+/-38% increase in 133Xe-CBF and a mean 19+/-27% increase in relative CBF (rCBF) by MR perfusion immediately after stent placement. Relative (percent) changes in MR-rCBF showed a close and linear correlation to those seen in 133Xe-CBF (r=0.91; R2=0.84; P=0.002). There was a trend for MR perfusion to underestimate change in CBF at higher relative changes in flow.

Conclusions: Bolus-tracking MR perfusion correlates with 133Xe-CBF in estimating postprocedural increases in blood flow but may underestimate the magnitude of the change with higher relative changes.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources