Assigning product ions from complex MS/MS spectra: the importance of mass uncertainty and resolving power
- PMID: 15694769
- DOI: 10.1016/j.jasms.2004.10.001
Assigning product ions from complex MS/MS spectra: the importance of mass uncertainty and resolving power
Abstract
This study offers a unique insight into the mass accuracy and resolving power requirements in MS/MS analyses of complex product ion spectra. In the examples presented here, accurate mass assignments were often difficult because of multiple isobaric interferences and centroid mass shifts. The question then arose whether the resolving power of a medium-resolution quadrupole time-of flight (QqTOF) is sufficient or high-resolution Fourier-transform ion cyclotron resonance (FT-ICR) is required for unambiguous assignments of elemental compositions. For the comparison, two paralytic shellfish poisons (PSP), saxitoxin (STX) and neosaxitoxin (NEO), with molecular weights of 299 and 315 g x mol(-1), respectively, were chosen because of the high peak density in their MS/MS spectra. The assessment of QqTOF collision-induced dissociation spectra and FT-ICR infrared multiphoton dissociation spectra revealed that several intrinsic dissociation pathways leading to isobaric fragment ions could not be resolved with the QqTOF instrument and required FT-ICR to distinguish very close mass differences. The second major source of interferences was M + 1 species originating from coactivated 13C12Cc-1 ion contributions of the protonated molecules of the PSPs. The problem in QqTOF MS results from internal mass calibration when the MH+ ions of analyte and mass calibrant are activated at the same time in the collision or trapping cell. Although FT-ICR MS readily resolved these interfering species, the QqTOF did not provide resolving power >20,000 (full width at half maximum) required to separate most isobaric species. We were able to develop a semi-internal QqTOF calibration technique that activated only the isolated 12C isotope species of the protonated molecules, thus reducing the M + 1 interferences significantly. In terms of overall automated elemental formulas assignment, FT-ICR MS achieved the first formula hit for 100% of the product ions, whereas the QqTOF MS hit rate was only 56 and 65% for STX and NEO product ions, respectively. External mass calibration from commercial FT-ICR and QqTOF instruments gave similar results.
Similar articles
-
Fourier transform ion cyclotron resonance mass spectrometry for the characterisation of kavalactones in the kava plant: elemental formulae confirmation by dual spray accurate mass measurement and structural confirmation by infrared multiphoton dissociation and sustained off-resonance irradiation collision induced dissociation.Eur J Mass Spectrom (Chichester). 2006;12(4):223-33. doi: 10.1255/ejms.808. Eur J Mass Spectrom (Chichester). 2006. PMID: 17057279
-
Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry.Anal Bioanal Chem. 2013 Jan;405(1):51-61. doi: 10.1007/s00216-012-6422-8. Epub 2012 Oct 18. Anal Bioanal Chem. 2013. PMID: 23076397 Review.
-
High mass accuracy and high mass resolving power FT-ICR secondary ion mass spectrometry for biological tissue imaging.Anal Bioanal Chem. 2013 Jul;405(18):6069-76. doi: 10.1007/s00216-013-7048-1. Epub 2013 May 19. Anal Bioanal Chem. 2013. PMID: 23685962
-
Activation of large ions in FT-ICR mass spectrometry.Mass Spectrom Rev. 2005 Mar-Apr;24(2):135-67. doi: 10.1002/mas.20012. Mass Spectrom Rev. 2005. PMID: 15389858 Review.
-
Uncoiling collagen: a multidimensional mass spectrometry study.Analyst. 2016 Jan 7;141(1):157-65. doi: 10.1039/c5an01757b. Epub 2015 Nov 16. Analyst. 2016. PMID: 26568361
Cited by
-
Structural Characterization of Carbohydrates by Fourier Transform Tandem Mass Spectrometry.Curr Proteomics. 2011 Dec 1;8(4):297-308. doi: 10.2174/157016411798220826. Curr Proteomics. 2011. PMID: 22389641 Free PMC article.
-
Neutral fragment filtering for rapid identification of new diester-diterpenoid alkaloids in roots of Aconitum carmichaeli by ultra-high-pressure liquid chromatography coupled with linear ion trap-orbitrap mass spectrometry.PLoS One. 2012;7(12):e52352. doi: 10.1371/journal.pone.0052352. Epub 2012 Dec 21. PLoS One. 2012. PMID: 23285005 Free PMC article.
-
Advances in structure elucidation of small molecules using mass spectrometry.Bioanal Rev. 2010 Dec;2(1-4):23-60. doi: 10.1007/s12566-010-0015-9. Epub 2010 Aug 21. Bioanal Rev. 2010. PMID: 21289855 Free PMC article.
-
Intriguing differences in the gas-phase dissociation behavior of protonated and deprotonated gonyautoxin epimers.J Am Soc Mass Spectrom. 2011 Nov;22(11):2011-20. doi: 10.1007/s13361-011-0223-8. Epub 2011 Aug 16. J Am Soc Mass Spectrom. 2011. PMID: 21952766
-
Dereplication of microbial metabolites through database search of mass spectra.Nat Commun. 2018 Oct 2;9(1):4035. doi: 10.1038/s41467-018-06082-8. Nat Commun. 2018. PMID: 30279420 Free PMC article.
References
Publication types