Considerations on isolation rooms and alternative pressure ventilation systems
- PMID: 15697008
Considerations on isolation rooms and alternative pressure ventilation systems
Abstract
The health-care facility environment is involved in disease transmission in essentially two different situations: 1. in cases where patients are immunocompromised and require protection from infections; 2. in cases of inadvertent exposure to environmental or airborne pathogens that can aggravate patients' existent disease and cause illness among health-care personnel. Environmental infection-control strategies and engineering controls can effectively prevent transmission of these infections. In particular the ventilation system is fundamental to the control of the concentration of airborne contaminants within a hospital isolation room because it establishes and maintains appropriate pressure differentials within special care areas of the building. Thus the incidence of health-care-associated infections can be minimized by adherence to ventilation standards suggested in the guidelines for specialized care environments such as Airborne Infection Isolation rooms (AII, as in situation 2 above), and Protective Environments (PE) rooms (as in situation 1 above). This report is a comparative review of the principal guidelines and strategies existing in the international scientific literature for the prevention of environment-associated infections in healthcare facilities using pressure differentials (positive pressure for PE rooms, negative pressure for AII rooms). The purpose of the review is also to investigate the state-of-the-art use of the "alternative pressure rooms", i.e., areas furnished with a ventilation system capable of switching pressure from positive to negative according to patients' needs. The results of the present analysis indicate an unenthusiastic reaction to these "alternative pressure rooms", although there is no scientific evidence against their use.
Similar articles
-
Development of an empirical model to aid in designing airborne infection isolation rooms.J Occup Environ Hyg. 2007 Mar;4(3):198-207. doi: 10.1080/15459620601177370. J Occup Environ Hyg. 2007. PMID: 17237025
-
A performance assessment of airborne infection isolation rooms.Am J Infect Control. 2007 Jun;35(5):324-31. doi: 10.1016/j.ajic.2006.10.012. Am J Infect Control. 2007. PMID: 17577480
-
Containment testing of isolation rooms.J Hosp Infect. 2004 Jul;57(3):228-32. doi: 10.1016/j.jhin.2004.01.032. J Hosp Infect. 2004. PMID: 15236852
-
Design of the environment of care for safety of patients and personnel: does form follow function or vice versa in the intensive care unit?Crit Care Med. 2010 Aug;38(8 Suppl):S388-98. doi: 10.1097/CCM.0b013e3181e6d0c1. Crit Care Med. 2010. PMID: 20647797 Review.
-
[State of the art and scientific evidence on the role of unidirectional airflow ventilation systems in reducing surgical site infections].Ann Ig. 2010 Jul-Aug;22(4):369-81. Ann Ig. 2010. PMID: 21425647 Review. Italian.
Publication types
MeSH terms
LinkOut - more resources
Medical