Abstract
Background: Supplementary polyglecaprone 25 (Monocryl) monofilaments were added to a lightweight pure monofilament polypropylene mesh (PP mesh) to improve intraoperative handling (PP+M mesh). This study was designed to evaluate the influence of this additional supplementation on the biocompatibility in a rodent animal model.
Methods: Two mesh materials, a composite mesh (PP+M) and the pure polypropylene variant (PP), were compared after subcutaneous implantation in a standardized rat model. Histological analysis of the inflammatory response was performed after 28, 56 and 84 days of implantation. Material absorption, inflammatory tissue reaction, fibrosis and granuloma formation were investigated, as well as the percentage of proliferating and apoptotic cells at the interface.
Results: Both mesh materials showed a slight foreign body reaction involving mainly macrophages and foreign body giant cells. Total absorption of the Monocryl filaments of the PP+M mesh occurred between 56 and 84 days of implantation. Both the inflammatory and the fibrotic reaction were decreased (n.s.) in the PP+M mesh group compared to the pure PP mesh. Whereas the percentage of proliferating cells showed no significant difference, the rate of apoptotic cells was significantly decreased in the PP+M mesh group over the whole implantation period.
Conclusion: Compared to the pure polypropylene mesh, our data confirm that the use of a polypropylene mesh supplemented with absorbable Monocryl filaments is feasible without additional short-term mesh-related complications in the experimental model or negative side effects on biocompatibility.
Similar articles
-
In vivo response to polypropylene following implantation in animal models: a review of biocompatibility.Int Urogynecol J. 2017 Feb;28(2):171-180. doi: 10.1007/s00192-016-3029-1. Epub 2016 May 23. Int Urogynecol J. 2017. PMID: 27216918 Free PMC article. Review.
-
Titanium coating of a polypropylene mesh for hernia repair: effect on biocompatibilty.Hernia. 2005 May;9(2):115-9. doi: 10.1007/s10029-004-0292-8. Epub 2004 Dec 4. Hernia. 2005. PMID: 15583967
-
Vypro II mesh in hernia repair: impact of polyglactin on long-term incorporation in rats.Eur Surg Res. 2003 Sep-Oct;35(5):445-50. doi: 10.1159/000072230. Eur Surg Res. 2003. PMID: 12928603
-
In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs.Surg Endosc. 2004 Feb;18(2):211-20. doi: 10.1007/s00464-003-8113-1. Epub 2003 Dec 29. Surg Endosc. 2004. PMID: 14691711
-
The argument for lightweight polypropylene mesh in hernia repair.Surg Innov. 2005 Mar;12(1):63-9. doi: 10.1177/155335060501200109. Surg Innov. 2005. PMID: 15846448 Review.
Cited by
-
In vivo response to polypropylene following implantation in animal models: a review of biocompatibility.Int Urogynecol J. 2017 Feb;28(2):171-180. doi: 10.1007/s00192-016-3029-1. Epub 2016 May 23. Int Urogynecol J. 2017. PMID: 27216918 Free PMC article. Review.
-
Impact of gentamicin-supplemented polyvinylidenfluoride mesh materials on MMP-2 expression and tissue integration in a transgenic mice model.Langenbecks Arch Surg. 2010 Apr;395(4):413-20. doi: 10.1007/s00423-010-0601-x. Epub 2010 Feb 13. Langenbecks Arch Surg. 2010. PMID: 20155364
-
Mesh contraction: in vivo documentation of changes in apparent surface area utilizing meshes visible on magnetic resonance imaging in the rabbit abdominal wall model.Int Urogynecol J. 2014 Jun;25(6):737-43. doi: 10.1007/s00192-013-2293-6. Epub 2014 Jan 22. Int Urogynecol J. 2014. PMID: 24448724
-
Randomized clinical trial comparing lightweight mesh with heavyweight mesh for primary inguinal hernia repair.Hernia. 2013 Aug;17(4):471-7. doi: 10.1007/s10029-012-1009-z. Epub 2012 Nov 9. Hernia. 2013. PMID: 23138859 Clinical Trial.
-
Improving outcomes in hernia repair by the use of light meshes--a comparison of different implant constructions based on a critical appraisal of the literature.World J Surg. 2007 Jan;31(1):234-44. doi: 10.1007/s00268-006-0123-4. World J Surg. 2007. PMID: 17180568 Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous