Region and volume dependencies in spectral line width assessed by 1H 2D MR chemical shift imaging in the monkey brain at 7 T
- PMID: 15707787
- DOI: 10.1016/j.mri.2004.10.005
Region and volume dependencies in spectral line width assessed by 1H 2D MR chemical shift imaging in the monkey brain at 7 T
Abstract
High magnetic fields increase the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS). In contrast, spectral peaks are broadened in vivo at higher field strength due to stronger susceptibility-induced effects. Strategies to minimize the spectral line width are therefore of critical importance. In the present study, 1H 2D chemical shift imaging at short echo times was performed in the macaque monkey brain at 7 T. Large brain coverage was obtained at high spatial resolution with voxel sizes down to 50 microl being able to quantify up to nine metabolites in vivo with good reliability. Measured line widths of metabolites decreased from 14.2 to 7.6 Hz with voxel volumes of 3.14 ml to 50 microl (at increased spatial resolution). The line width distribution of the metabolites (7.6+/-1.6 Hz, ranging from 5.5 to 10 Hz) was considerably smaller compared to that of water (10.6+/-2.4 Hz) and was also smaller than reported in 1H MRS at 7 T in the human brain. Our study showed that even in well-shimmed areas assumed to have minimal macroscopic susceptibility variations, spectral line widths are tissue-specific exhibiting considerable regional variation. Therefore, an overall improvement of a gross spectral line width--directly correlated with improved spectral quality--can only be achieved when voxel volumes are significantly reduced. Our line width optimization was sufficient to permit clear glutamate (Glu)-glutamine separation, yielding distinct Glu maps for brain areas including regions of greatly different Glu concentration (e.g., ventricles vs. surrounding tissue).
Similar articles
-
3.0-T functional brain imaging: a 5-year experience.Radiol Med. 2007 Feb;112(1):97-112. doi: 10.1007/s11547-007-0124-x. Epub 2007 Feb 22. Radiol Med. 2007. PMID: 17310287 English, Italian.
-
High-field localized 1H NMR spectroscopy in the anesthetized and in the awake monkey.Magn Reson Imaging. 2004 Dec;22(10):1361-72. doi: 10.1016/j.mri.2004.10.002. Magn Reson Imaging. 2004. PMID: 15707786
-
[Quantitation of glutamate in the brain by using MR proton spectroscopy at 1.5 T and 3 T].Rofo. 2008 Aug;180(8):722-32. doi: 10.1055/s-2008-1027422. Epub 2008 May 29. Rofo. 2008. PMID: 18512190 German.
-
High-field proton MRS of human brain.Eur J Radiol. 2003 Nov;48(2):146-53. doi: 10.1016/j.ejrad.2003.08.009. Eur J Radiol. 2003. PMID: 14680905 Review.
-
Detection of hidden metabolites by localized proton magnetic resonance spectroscopy in vivo.Technol Health Care. 1997 Dec;5(6):471-91. Technol Health Care. 1997. PMID: 9696165 Review.
Cited by
-
Regional metabolite T2 in the healthy rhesus macaque brain at 7T.Magn Reson Med. 2008 May;59(5):1165-9. doi: 10.1002/mrm.21574. Magn Reson Med. 2008. PMID: 18429024 Free PMC article.
-
On the voxel size and magnetic field strength dependence of spectral resolution in magnetic resonance spectroscopy.Magn Reson Imaging. 2009 Feb;27(2):222-32. doi: 10.1016/j.mri.2008.06.009. Epub 2008 Aug 6. Magn Reson Imaging. 2009. PMID: 18687553 Free PMC article.
-
Cross-sectional and longitudinal reproducibility of rhesus macaque brain metabolites: a proton MR spectroscopy study at 3 T.Magn Reson Med. 2011 Jun;65(6):1522-31. doi: 10.1002/mrm.22867. Epub 2011 Feb 17. Magn Reson Med. 2011. PMID: 21337426 Free PMC article.
-
Metabolite proton T(2) mapping in the healthy rhesus macaque brain at 3 T.Magn Reson Med. 2009 Nov;62(5):1292-9. doi: 10.1002/mrm.22117. Magn Reson Med. 2009. PMID: 19780178 Free PMC article.
-
Proton MR spectroscopic imaging of rhesus macaque brain in vivo at 7T.Magn Reson Med. 2008 Apr;59(4):692-9. doi: 10.1002/mrm.21554. Magn Reson Med. 2008. PMID: 18302225 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical