Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Jan;29(1):21-34.
doi: 10.1016/j.compmedimag.2004.07.008. Epub 2005 Jan 24.

A system for brain tumor volume estimation via MR imaging and fuzzy connectedness

Affiliations

A system for brain tumor volume estimation via MR imaging and fuzzy connectedness

Jianguo Liu et al. Comput Med Imaging Graph. 2005 Jan.

Abstract

This paper presents a method for the precise, accurate and efficient quantification of brain tumor (glioblastomas) via MRI that can be used routinely in the clinic. Tumor volume is considered useful in evaluating disease progression and response to therapy, and in assessing the need for changes in treatment plans. We use multiple MRI protocols including FLAIR, T1, and T1 with Gd enhancement to gather information about different aspects of the tumor and its vicinity. These include enhancing tissue, nonenhancing tumor, edema, and combinations of edema and tumor. We have adapted the fuzzy connectedness framework for tumor segmentation in this work and the method requires only limited user interaction in routine clinical use. The system has been tested for its precision, accuracy, and efficiency, utilizing 10 patient studies. The percent coefficient of variation (% CV) in volume due to operator subjectivity in specifying seeds for fuzzy connectedness segmentation is less than 1%. The mean operator and computer time required per study for estimating the volumes of both edema and enhancing tumor is about 16 min. The software package is designed to run under operator supervision. Delineation has been found to agree with the operators' visual inspection most of the time except in some cases when the tumor is close to the boundary of the brain. In the latter case, the scalp, surgical scar, or orbital contents are included in the delineation, and an operator has to exclude this manually. The methodology is rapid, robust, consistent, yielding highly reproducible measurements, and is likely to become part of the routine evaluation of brain tumor patients in our health system.

PubMed Disclaimer

Publication types

LinkOut - more resources