Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery
- PMID: 15719975
- DOI: 10.1118/1.1836331
Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery
Abstract
A mobile isocentric C-arm (Siemens PowerMobil) has been modified in our laboratory to include a large area flat-panel detector (in place of the x-ray image intensifier), providing multi-mode fluoroscopy and cone-beam computed tomography (CT) imaging capability. This platform represents a promising technology for minimally invasive, image-guided surgical procedures where precision in the placement of interventional tools with respect to bony and soft-tissue structures is critical. The image quality and performance in surgical guidance was investigated in pre-clinical evaluation in image-guided spinal surgery. The control, acquisition, and reconstruction system are described. The reproducibility of geometric calibration, essential to achieving high three-dimensional (3D) image quality, is tested over extended time scales (7 months) and across a broad range in C-arm angulation (up to 45 degrees), quantifying the effect of improper calibration on spatial resolution, soft-tissue visibility, and image artifacts. Phantom studies were performed to investigate the precision of 3D localization (viz., fiber optic probes within a vertebral body) and effect of lateral projection truncation (limited field of view) on soft-tissue detectability in image reconstructions. Pre-clinical investigation was undertaken in a specific spinal procedure (photodynamic therapy of spinal metastases) in five animal subjects (pigs). In each procedure, placement of fiber optic catheters in two vertebrae (L1 and L2) was guided by fluoroscopy and cone-beam CT. Experience across five procedures is reported, focusing on 3D image quality, the effects of respiratory motion, limited field of view, reconstruction filter, and imaging dose. Overall, the intraoperative cone-beam CT images were sufficient for guidance of needles and catheters with respect to bony anatomy and improved surgical performance and confidence through 3D visualization and verification of transpedicular trajectories and tool placement. Future investigation includes improvement in image quality, particularly regarding x-ray scatter, motion artifacts and field of view, and integration with optical tracking and navigation systems.
Similar articles
-
Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.Med Phys. 2006 Oct;33(10):3767-80. doi: 10.1118/1.2349687. Med Phys. 2006. PMID: 17089842
-
Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance.Med Phys. 2011 Aug;38(8):4563-74. doi: 10.1118/1.3597566. Med Phys. 2011. PMID: 21928628 Free PMC article.
-
Flat-panel cone-beam computed tomography for image-guided radiation therapy.Int J Radiat Oncol Biol Phys. 2002 Aug 1;53(5):1337-49. doi: 10.1016/s0360-3016(02)02884-5. Int J Radiat Oncol Biol Phys. 2002. PMID: 12128137
-
AAPM Task Group Report 238: 3D C-arms with volumetric imaging capability.Med Phys. 2023 Aug;50(8):e904-e945. doi: 10.1002/mp.16245. Epub 2023 Feb 20. Med Phys. 2023. PMID: 36710257 Free PMC article. Review.
-
[Image quality of cone-beam CT].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2011;67(11):1468-72. doi: 10.6009/jjrt.67.1468. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2011. PMID: 22104241 Review. Japanese. No abstract available.
Cited by
-
Magnetorheological Fluids Actuated Haptic-Based Teleoperated Catheter Operating System.Micromachines (Basel). 2018 Sep 13;9(9):465. doi: 10.3390/mi9090465. Micromachines (Basel). 2018. PMID: 30424398 Free PMC article.
-
Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.Med Phys. 2008 Aug;35(8):3728-39. doi: 10.1118/1.2952653. Med Phys. 2008. PMID: 18777932 Free PMC article. Review.
-
Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach.Med Phys. 2011 Apr;38(4):1785-98. doi: 10.1118/1.3555037. Med Phys. 2011. PMID: 21626913 Free PMC article.
-
On mixed reality environments for minimally invasive therapy guidance: systems architecture, successes and challenges in their implementation from laboratory to clinic.Comput Med Imaging Graph. 2013 Mar;37(2):83-97. doi: 10.1016/j.compmedimag.2012.12.002. Epub 2013 Feb 8. Comput Med Imaging Graph. 2013. PMID: 23632059 Free PMC article.
-
Artifact reduction in short-scan CBCT by use of optimization-based reconstruction.Phys Med Biol. 2016 May 7;61(9):3387-406. doi: 10.1088/0031-9155/61/9/3387. Epub 2016 Apr 5. Phys Med Biol. 2016. PMID: 27046218 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical