Influence of vessel diameter on the efficacy of distal protection devices during saphenous vein graft intervention
- PMID: 15721112
- DOI: 10.1016/j.amjcard.2004.10.044
Influence of vessel diameter on the efficacy of distal protection devices during saphenous vein graft intervention
Abstract
We sought to determine the influence of vessel diameter on the efficacy of distal protection devices during saphenous vein graft intervention. From the Filterwire EX Randomized Evaluation trial, in which patients who underwent saphenous vein graft stenting were randomized to distal protection with the GuardWire or FilterWire EX, outcomes in 572 patients were examined in vessel size tertiles. The 30-day composite incidence of major adverse cardiac events (MACEs) increased with vessel size and was 6.9%, 9.7%, and 14.9% in the smallest, middle, and largest tertiles, respectively (p = 0.04). MACE rates were relatively vessel size independent for the GuardWire but increased steadily with vessel size with the FilterWire EX. In the smallest tertile, MACEs were reduced by 71% with the FilterWire EX compared with the GuardWire (p = 0.05), with the devices showing similar event rates in the other tertiles.
Similar articles
-
Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts.Circulation. 2003 Aug 5;108(5):548-53. doi: 10.1161/01.CIR.0000080894.51311.0A. Epub 2003 Jul 21. Circulation. 2003. PMID: 12874191 Clinical Trial.
-
Six-month outcomes after percutaneous intervention for lesions in aortocoronary saphenous vein grafts using distal protection devices: results from the FIRE trial.Am Heart J. 2006 Apr;151(4):915.e1-7. doi: 10.1016/j.ahj.2005.09.018. Am Heart J. 2006. PMID: 16569562 Clinical Trial.
-
Platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment during saphenous vein graft stenting: differential effects after randomization to occlusion or filter-based embolic protection.Eur Heart J. 2006 Apr;27(8):920-8. doi: 10.1093/eurheartj/ehi736. Epub 2006 Jan 16. Eur Heart J. 2006. PMID: 16415300 Clinical Trial.
-
Embolic protection devices in saphenous percutaneous intervention.EuroIntervention. 2009 May;5 Suppl D:D45-50. EuroIntervention. 2009. PMID: 19736070 Review.
-
Saphenous vein graft interventions: strategies and devices to minimize distal embolization.Minerva Cardioangiol. 2012 Apr;60(2):157-66. Minerva Cardioangiol. 2012. PMID: 22495164 Review.
Cited by
-
FilterWire distal embolic protection device for vein graft stenting: initial single-center experience.Clin Cardiol. 2005 Dec;28(12):556-60. doi: 10.1002/clc.4960281204. Clin Cardiol. 2005. PMID: 16405198 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical