Randomized Controlled Trial
. 2005 Apr;390(2):114-20.
doi: 10.1007/s00423-005-0543-x. Epub 2005 Feb 19.

Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial

Affiliations
Randomized Controlled Trial

Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial

Andrea Frilling et al. Langenbecks Arch Surg. 2005 Apr.

Abstract

Background and aims: A new carrier-bound fibrin sealant, TachoSil, is expected to be efficacious and safe as a haemostatic treatment in hepatic resection.

Design: A prospective, randomised, open and controlled multicentre trial with intraoperative as well as postoperative assessment of efficacy and a 1 month follow-up period.

Setting: Tertiary care centres.

Patients/methods: One hundred and twenty-one patients requiring secondary haemostasis during planned liver resection. Patients with coagulation disorders and patients with persistent major bleeding after primary haemostatic measures were excluded.

Intervention: Application of either carrier-bound fibrin sealant (n=59) or argon beamer (argon beam coagulator) (n=62) as secondary haemostatic treatment.

Main outcome measure: Time to intraoperative haemostasis.

Results: There was a significant superiority of TachoSil over argon beamer with regard to time to haemostasis (3.9 min, median 3.0, range 3-20 min vs 6.3 min, median 4.0, range 3-39 min) (P=0.0007). Haemoglobin concentration of drainage fluid was significantly lower on day 2 after surgery in TachoSil patients (1.1 mmol/l) than in argon beamer patients (2.3 mmol/l) (P=0.012). Overall, the frequency and causality of adverse events did not differ between the two treatment groups.

Conclusion: TachoSil is superior to argon beamer in obtaining effective and fast intraoperative haemostasis. The safety data show TachoSil to be tolerable and safe for haemostatic treatment in liver resection.

PubMed Disclaimer

References

    1. Surg Today. 2002;32(1):48-52 - PubMed
    1. Br J Surg. 2000 Jun;87(6):790-5 - PubMed
    1. Br J Surg. 1993 Dec;80(12):1563-5 - PubMed
    1. Int Surg. 1996 Jul-Sep;81(3):316-9 - PubMed
    1. Br J Surg. 1996 Nov;83(11):1526-9 - PubMed

Publication types

LinkOut - more resources