Free breathing 3D balanced FFE coronary magnetic resonance angiography with prolonged cardiac acquisition windows and intra-RR motion correction
- PMID: 15723401
- DOI: 10.1002/mrm.20397
Free breathing 3D balanced FFE coronary magnetic resonance angiography with prolonged cardiac acquisition windows and intra-RR motion correction
Abstract
A shortcoming of today's coronary magnetic resonance angiography (MRA) is its low total scan efficiency (<5%), as only small well-defined fractions of the respiratory (50%) and cardiac (10%) cycle are used for data acquisition. These precautions are necessary to prevent blurring and artifacts related to respiratory and cardiac motion. Hence, scan times range from 4 to 9 min, which may not be tolerated by patients. To overcome this drawback, an ECG-triggered, navigator-gated free breathing radial 3D balanced FFE sequence with intra-RR motion correction is investigated in this study. Scan efficiency is increased by using a long cardiac acquisition window during the RR interval. This allows the acquisition of a number of independent k-space segments during each cardiac cycle. The intersegment motion is corrected using a self-guided epicardial fat tracking procedure in a postprocessing step. Finally, combining the motion-corrected segments forms a high-resolution image. Experiments on healthy volunteers are presented to show the basic feasibility of this approach.
(c) 2005 Wiley-Liss, Inc.
Similar articles
-
Reduction of respiratory motion artifacts for free-breathing whole-heart coronary MRA by weighted iterative reconstruction.Magn Reson Med. 2015 May;73(5):1885-95. doi: 10.1002/mrm.25321. Epub 2014 Jun 9. Magn Reson Med. 2015. PMID: 24912763
-
Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction.Magn Reson Med. 2005 Aug;54(2):476-80. doi: 10.1002/mrm.20557. Magn Reson Med. 2005. PMID: 16032682
-
Fast isotropic volumetric coronary MR angiography using free-breathing 3D radial balanced FFE acquisition.Magn Reson Med. 2004 Jul;52(1):197-203. doi: 10.1002/mrm.20128. Magn Reson Med. 2004. PMID: 15236387
-
[3D motion adapted gating: a new navigator technique to shorten the acquisition time for coronary MRA].Rofo. 2005 Mar;177(3):350-7. doi: 10.1055/s-2005-857882. Rofo. 2005. PMID: 15719296 German.
-
High efficiency free-breathing 3D thoracic aorta vessel wall imaging using self-gating image reconstruction.Magn Reson Imaging. 2024 Apr;107:80-87. doi: 10.1016/j.mri.2024.01.009. Epub 2024 Jan 17. Magn Reson Imaging. 2024. PMID: 38237694 Review.
Cited by
-
Free-breathing 3D steady-state free precession coronary magnetic resonance angiography: comparison of diaphragm and cardiac fat navigators.J Magn Reson Imaging. 2008 Aug;28(2):509-14. doi: 10.1002/jmri.21439. J Magn Reson Imaging. 2008. PMID: 18666215 Free PMC article.
-
High efficiency coronary MR angiography with nonrigid cardiac motion correction.Magn Reson Med. 2016 Nov;76(5):1345-1353. doi: 10.1002/mrm.26332. Epub 2016 Jul 25. Magn Reson Med. 2016. PMID: 27455164 Free PMC article.
-
Automated adaptive detection and reconstruction of quiescent cardiac phases in free-running whole-heart acquisitions using Synchronicity Maps from PHysiological mOtioN In Cine (SYMPHONIC) MRI.MAGMA. 2025 Aug 19. doi: 10.1007/s10334-025-01289-5. Online ahead of print. MAGMA. 2025. PMID: 40828222
-
Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla.Eur Radiol. 2007 Feb;17(2):339-46. doi: 10.1007/s00330-006-0368-1. Epub 2006 Oct 5. Eur Radiol. 2007. PMID: 17021711
-
Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis.Eur Radiol. 2006 Jan;16(1):1-14. doi: 10.1007/s00330-005-2886-7. Epub 2005 Aug 25. Eur Radiol. 2006. PMID: 16132919 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources