Hydrodynamics-induced variability in the USP apparatus II dissolution test
- PMID: 15725550
- DOI: 10.1016/j.ijpharm.2004.08.003
Hydrodynamics-induced variability in the USP apparatus II dissolution test
Abstract
The USP tablet dissolution test is an analytical tool used for the verification of drug release processes and formulation selection within the pharmaceutical industry. Given the strong impact of this test, it is surprising that operating conditions and testing devices have been selected empirically. In fact, the flow phenomena in the USP test have received little attention in the past. An examination of the hydrodynamics in the USP apparatus II shows that the device is highly vulnerable to mixing problems that can affect testing performance and consistency. Experimental and computational techniques reveal that the flow field within the device is not uniform, and dissolution results can vary dramatically with the position of the tablet within the vessel. Specifically, computations predict sharp variations in the shear along the bottom of the vessel where the tablet is most likely to settle. Experiments in which the tablet location was carefully controlled reveal that the variation of shear within the testing device can affect the measured dissolution rate.
Similar articles
-
Shear distribution and variability in the USP Apparatus 2 under turbulent conditions.Int J Pharm. 2004 Jul 26;279(1-2):9-17. doi: 10.1016/j.ijpharm.2004.03.033. Int J Pharm. 2004. PMID: 15234789
-
Shear-induced variability in the United States Pharmacopeia Apparatus 2: modifications to the existing system.AAPS J. 2006 Jan 3;7(4):E857-64. doi: 10.1208/aapsj070483. AAPS J. 2006. PMID: 16594638 Free PMC article.
-
Hydrodynamic investigation of USP dissolution test apparatus II.J Pharm Sci. 2007 Sep;96(9):2327-49. doi: 10.1002/jps.20818. J Pharm Sci. 2007. PMID: 17573698
-
Engineering tools for understanding the hydrodynamics of dissolution tests.Drug Dev Ind Pharm. 2003 Feb;29(2):231-9. doi: 10.1081/ddc-120016731. Drug Dev Ind Pharm. 2003. PMID: 12648020 Review.
-
Application of sequential injection analysis to pharmaceutical analysis.J Pharm Biomed Anal. 2006 Jan 23;40(1):16-34. doi: 10.1016/j.jpba.2005.10.006. Epub 2005 Dec 2. J Pharm Biomed Anal. 2006. PMID: 16326061 Review.
Cited by
-
Effects of Pump Pulsation on Hydrodynamic Properties and Dissolution Profiles in Flow-Through Dissolution Systems (USP 4).Pharm Res. 2016 Jun;33(6):1327-36. doi: 10.1007/s11095-016-1874-8. Epub 2016 Feb 11. Pharm Res. 2016. PMID: 26869175
-
The Effect of Sampling Cannula on In Vitro Dissolution Testing with USP Paddle Method.AAPS J. 2023 Apr 26;25(3):46. doi: 10.1208/s12248-023-00813-6. AAPS J. 2023. PMID: 37101085
-
Impact of Food and Drink Administration Vehicles on Paediatric Formulation Performance Part 2: Dissolution of Montelukast Sodium and Mesalazine Formulations.AAPS PharmSciTech. 2020 Oct 15;21(7):287. doi: 10.1208/s12249-020-01815-9. AAPS PharmSciTech. 2020. PMID: 33063245 Free PMC article.
-
Effects of Apex Size on Dissolution Profiles in the USP II Paddle Apparatus.AAPS PharmSciTech. 2023 Dec 29;25(1):9. doi: 10.1208/s12249-023-02722-5. AAPS PharmSciTech. 2023. PMID: 38158516
-
Modelling and Simulation of the Drug Release from a Solid Dosage Form in the Human Ascending Colon: The Influence of Different Motility Patterns and Fluid Viscosities.Pharmaceutics. 2021 Jun 10;13(6):859. doi: 10.3390/pharmaceutics13060859. Pharmaceutics. 2021. PMID: 34200574 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous