Gated technetium-99m methoxy-isobutylisonitrile perfusion imaging
- PMID: 1572743
- DOI: 10.1016/0167-5273(92)90181-2
Gated technetium-99m methoxy-isobutylisonitrile perfusion imaging
Abstract
Technetium-99m methoxy-isobutylisonitrile, has been shown to be a useful perfusion agent for detecting coronary artery disease. Gated acquisition of perfusion images may remove motion artefact and improve detection. We compared the results of sensitivity and specificity for detecting coronary artery disease using perfusion images from the whole cardiac cycle (ungated) or from end-diastolic (gated) frames in 46 subjects, 31 with significant coronary disease and 15 with normal coronary arteries. There was no significant difference in detection of patients with coronary disease between the ungated and end-diastolic images: 25/31 with the ungated image and 28/31 with the end-diastolic. An improvement was made in detecting defects in the left anterior descending artery territory: 17/20 with the end-diastolic vs 11/20 with the ungated image (P less than 0.05) and in the right coronary artery region: 16/21 vs 10/21 (P less than 0.05), with an overall improvement in detecting regions supplied by stenosed coronary arteries: 45/55 end-diastolic vs 31/55 ungated (P less than 0.01). These results suggest use of the end-diastolic frame can significantly enhance the diagnostic capacity of methoxy-isobutylisonitrile perfusion imaging.
Similar articles
-
Exercise myocardial perfusion scintigraphy with technetium-99m methoxy isobutylisonitrile: a comparative study with thallium-201.Int J Cardiol. 1990 Jan;26(1):93-102. doi: 10.1016/0167-5273(90)90252-z. Int J Cardiol. 1990. PMID: 2298522
-
Evaluation of changes in myocardial perfusion and function on exercise in patients with coronary artery disease by gated MIBI scintigraphy.Br Heart J. 1993 Jul;70(1):22-6. doi: 10.1136/hrt.70.1.22. Br Heart J. 1993. PMID: 8037994 Free PMC article.
-
Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.Am J Cardiol. 1990 Oct 16;66(13):55E-62E. doi: 10.1016/0002-9149(90)90613-6. Am J Cardiol. 1990. PMID: 2145748 Review.
-
The clinical usefulness of electrocardiogram-gated Tc-99m methoxy-isobutyl-isonitrile images in the detection of basal wall motion abnormalities and reversibility of stress induced perfusion defects.Int J Card Imaging. 1992;8(2):131-41. doi: 10.1007/BF01137534. Int J Card Imaging. 1992. PMID: 1629639
-
State-of-the-art myocardial perfusion imaging.Cardiol Clin. 1994 May;12(2):199-222. Cardiol Clin. 1994. PMID: 8033173 Review.
Cited by
-
Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging.Eur J Nucl Med. 1995 Jan;22(1):40-8. doi: 10.1007/BF00997246. Eur J Nucl Med. 1995. PMID: 7698154
-
The influence of gating on measurements of myocardium at risk and infarct size during acute myocardial infarction by tomographic technetium 99m-labeled sestamibi imaging.J Nucl Cardiol. 1995 May-Jun;2(3):207-16. doi: 10.1016/s1071-3581(05)80057-1. J Nucl Cardiol. 1995. PMID: 9420790
-
Diagnostic value and incremental contribution of bicycle exercise, first-pass radionuclide angiography, and 99mTc-labeled sestamibi single-photon emission computed tomography in the identification of coronary artery disease in patients without infarction.J Nucl Cardiol. 1996 Nov-Dec;3(6 Pt 1):464-74. doi: 10.1016/s1071-3581(96)90056-2. J Nucl Cardiol. 1996. PMID: 8989671
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources