Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2005 Jan;50(1):45-8.

Office hysteroscopy: comparison of 2.7- and 4-mm hysteroscopes for acceptability, feasibility and diagnostic accuracy

Affiliations
  • PMID: 15730173
Clinical Trial

Office hysteroscopy: comparison of 2.7- and 4-mm hysteroscopes for acceptability, feasibility and diagnostic accuracy

Sandro Rullo et al. J Reprod Med. 2005 Jan.

Abstract

Objective: To compare 2.7- and 4-mm rigid optics, with 3- and 5-mm outer sheaths, respectively, in office diagnostic hysteroscopy by evaluating pain, patient tolerability, optical view and diagnostic accuracy of the procedure.

Study design: Three hundred seventy-one consecutive patients undergoing hysteroscopy were included in a prospective, randomized clinical trial, and the outcomes were analyzed. A saline solution was used as the distension medium. The t test for unpaired samples, chi2 tables of contingency and ANOVA 2 x 3 were used where appropriate. The study took place at Tor Vergata University Hospital of Rome, Rome, Italy. The 371 women were referred consecutively for suspected endometrial pathologies and were separated into 2 groups. Diagnostic accuracy of the hysteroscopic procedure, pain experienced by the 2 groups (as assessed by a visual analogue score) and patient acceptability were assessed with a questionnaire.

Results: Satisfactory hysteroscopy was achieved in 253 of 310 patients with a 2.7-mm hysteroscope and in 47 of 61 patients with a 4-mm hysteroscope. This difference was not significant. Menopausal status was the most important factor influencing the practicability of the hysteroscopic procedure (p < 0.001).

Conclusion: The narrower-diameter hysteroscopes tended to lower the incidence of pain associated with office hysteroscopy, but this was not significant. Parity did not show any influence on hysteroscopic practicability. Menopausal status was the most important factor influencing the feasibility of the hysteroscopic procedure.

PubMed Disclaimer

Comment in

  • Outpatient hysteroscopy.
    Di Spiezio Sardo A, Guida M, Nappi C, Magos A. Di Spiezio Sardo A, et al. J Reprod Med. 2006 Apr;51(4):331; author reply 331-2. J Reprod Med. 2006. PMID: 16737032 No abstract available.

Publication types

LinkOut - more resources