Correction of accurate mass measurement for target compound verification by quadrupole time-of-flight mass spectrometry
- PMID: 15734334
- DOI: 10.1016/j.jasms.2004.11.022
Correction of accurate mass measurement for target compound verification by quadrupole time-of-flight mass spectrometry
Abstract
The aim of this work is to evaluate quadrupole/time-of-flight (QTOF) mass spectrometry for simultaneous measurement of accurate mass and quantification of a target by using a stable isotopically labeled internal standard. Mixtures of caffeine and (13)C(3)-caffeine (internal standard) at different concentration ratios were analyzed by capillary HPLC/QTOF. A calibration plot for quantification is linear over a factor of 20. Without invoking any correction scheme, the mass accuracy seriously degraded when the ratio of the mass standard to the test compound was not unity. The accuracy could be restored to approximately 2 ppm by using a quadratic function to correct the measured mass as a function of the measured signal ratio of target and internal calibrant.
Similar articles
-
Liquid chromatography/electrospray ionization tandem mass spectrometry assay for determination of nicotine and metabolites, caffeine and arecoline in breast milk.Rapid Commun Mass Spectrom. 2007;21(16):2693-703. doi: 10.1002/rcm.3137. Rapid Commun Mass Spectrom. 2007. PMID: 17640086
-
Sub parts-per-million mass measurement accuracy of intact proteins and product ions achieved using a dual electrospray ionization quadrupole fourier transform ion cyclotron resonance mass spectrometer.J Am Soc Mass Spectrom. 2007 Jan;18(1):1-7. doi: 10.1016/j.jasms.2006.08.014. Epub 2006 Sep 18. J Am Soc Mass Spectrom. 2007. PMID: 16979902
-
Matrix effects on accurate mass measurements of low-molecular weight compounds using liquid chromatography-electrospray-quadrupole time-of-flight mass spectrometry.J Mass Spectrom. 2006 Mar;41(3):289-94. doi: 10.1002/jms.984. J Mass Spectrom. 2006. PMID: 16470723
-
Stereospecific determination of cis- and trans-resveratrol in rat plasma by HPLC: application to pharmacokinetic studies.Biomed Chromatogr. 2007 Mar;21(3):257-65. doi: 10.1002/bmc.747. Biomed Chromatogr. 2007. PMID: 17294509
-
Selection of internal standards for accurate quantification of complex lipid species in biological extracts by electrospray ionization mass spectrometry-What, how and why?Mass Spectrom Rev. 2017 Nov;36(6):693-714. doi: 10.1002/mas.21492. Epub 2016 Jan 15. Mass Spectrom Rev. 2017. PMID: 26773411 Free PMC article. Review.
Cited by
-
Structural Characterization and Electrochemical Studies of Selected Alkaloid N-Oxides.Molecules. 2024 Jun 7;29(12):2721. doi: 10.3390/molecules29122721. Molecules. 2024. PMID: 38930787 Free PMC article.
-
Accurate mass measurements in proteomics.Chem Rev. 2007 Aug;107(8):3621-53. doi: 10.1021/cr068288j. Epub 2007 Jul 25. Chem Rev. 2007. PMID: 17649984 Free PMC article. Review. No abstract available.
-
Automated sub-ppm mass accuracy on an ESI-TOF for use with drug discovery compound libraries.J Am Soc Mass Spectrom. 2007 Sep;18(9):1612-6. doi: 10.1016/j.jasms.2007.06.001. Epub 2007 Jun 16. J Am Soc Mass Spectrom. 2007. PMID: 17629494
-
Identification of novel fluorochemicals in aqueous film-forming foams used by the US military.Environ Sci Technol. 2012 Jul 3;46(13):7120-7. doi: 10.1021/es301465n. Epub 2012 Jun 15. Environ Sci Technol. 2012. PMID: 22681548 Free PMC article.
-
Elimination of systematic mass measurement errors in liquid chromatography-mass spectrometry based proteomics using regression models and a priori partial knowledge of the sample content.Anal Chem. 2008 Feb 1;80(3):693-706. doi: 10.1021/ac701863d. Epub 2007 Dec 29. Anal Chem. 2008. PMID: 18163597 Free PMC article.
References
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources