Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Mar;49(2):179-93.
doi: 10.1093/annhyg/meh082.

Evaluation of facial features on particle inhalation

Affiliations
Comparative Study

Evaluation of facial features on particle inhalation

T Renée Anthony et al. Ann Occup Hyg. 2005 Mar.

Abstract

Computational fluid dynamics (CFD) and numerical investigations of particle inhalability and contaminant exposure have used simple geometrical surrogates for a breathing human form, but the effect of eliminating facial features has not been investigated. In this work, the velocity field and particle aspiration associated with two differently shaped mannequins were investigated to determine if an elliptical form was sufficient to represent the complexity of fluid flow associated with an inhaling human. Laser Doppler anemometry was used to measure velocity, and both optical sizing and gravimetric analysis were used to measure particle aspiration from an aerosol source. All tests were performed with continuous inhalation through the mouth, with the mannequin facing the 0.3 m s(-1) freestream. Although limitations in the laser Doppler optics prevented velocity measurements at distances <11 mm in front of the mannequin mouth opening, significant velocity differences were identified up to 20 mm in front of the mouth opening. This indicated that facial features affected the flow field near the face only. Owing to these differences, particle aspiration was compared between mannequins for three different velocity ratio conditions using an aerosol source. Even with relatively large variability in the aspirated concentration in this study, the aspirated mass concentration was significantly less for the anatomical mannequin relative to the elliptical form. Thus, the simplified elliptical cylinder does not sufficiently characterize the fluid dynamics near the mouth of an inhaling human form at these limited test conditions. Future CFD and numerical simulations to investigate human aspiration of particles should incorporate the complex features of the human face to investigate adequately particle aspiration in low velocity environments.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances