Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Mar;93(3):503-11.
doi: 10.1160/TH04-08-0495.

Performance of magnetic resonance angiography in suspected acute pulmonary embolism

Affiliations
Comparative Study

Performance of magnetic resonance angiography in suspected acute pulmonary embolism

Alain Blum et al. Thromb Haemost. 2005 Mar.

Abstract

Pulmonary embolism (PE) is a common and potentially fatal disorder. Non-specific findings make the clinical diagnosis of PE difficult. To assess the diagnostic value and inter-observer agreement of magnetic resonance angiography (MRA) in a cohort of patients with suspected PE, we conducted a prospective clinical study. MRA was compared for sensitivity and specificity to a diagnostic strategy including clinical probability, D-dimer testing, spiral CT, ultrasound leg compression and pulmonary angiography. A total of 89 patients with clinically suspected PE were included: the clinical probability of PE was intermediate or high in 78, and low in the remaining 11. All patients underwent monoor multi-slice spiral CT and MRA with gadolinium injection (both within 24 hours of entry to the study). Anticoagulation was withheld in patients concerned about the strategy. All subjects were followed up for 3 months. MRA was read independently by two experienced teams of radiologists: one local and one from another university centre. Spiral CT was positive in 62 of 63 cases of confirmed PE. No patient with negative CT findings was positive ultrasonographically. Only one patient with a negative CT (and negative ultrasound) had a recurrent thromboembolic event. The first team diagnosed PE with MRA in 47 cases, with a sensitivity of 71% and a specificity of 92%; the second team obtained the diagnosis in 23 cases, with a sensitivity of 31% and a specificity of 85%. Inter-observer agreement between MRA reading was low: Kappa = 0.16 (-0.01 to 0.33); p = 0.07. In conclusion, compared with a non-invasive strategy based on spiral CT, the diagnostic value of MRA is limited by poor inter-observer agreement.

PubMed Disclaimer