Benzene analysis in workplace air using an FIA-based bacterial biosensor
- PMID: 15741079
- DOI: 10.1016/j.bios.2004.08.034
Benzene analysis in workplace air using an FIA-based bacterial biosensor
Abstract
A bacterial biosensor based on flow injection analysis (FIA) has been developed for the determination of benzene in workplace air samples. Benzene can be used by the bacteria Pseudomonas putida ML2 as a sole carbon source, and its aerobic degradation can be measured using a dissolved oxygen electrode. The bacterial cells were immobilised between two cellulose acetate membranes and fixed onto a Clark dissolved oxygen probe, which was inserted into a custom-made flow cell. The applicability of the biosensor for the analysis of air samples containing benzene was investigated. Air samples were collected from a controlled exposure room using charcoal adsorption tubes, and benzene extracted with solvent desorption using dimethylformamide (DMF). The biosensor displayed a linear detection range between 0.025 and 0.15 mM benzene based on standard solutions containing a maximum of 2% DMF, with a response time of 6 min. This linear detection range allows the analysis of air containing between 3 and 16 ppm benzene based on a 60-min sampling period. DMF proved to be compatible for use with the biosensor, causing minimal interference with the sensor response and causing no toxic effects on the bacterial cells. The FIA system was easily transported to an in situ location, and a correlation was obtained between the biosensor and gas chromatography (GC) results for the preliminary air samples investigated. Moreover, the biosensor displayed no interference to other benzene related compounds in the BTEX range. The results from this work have shown that the biosensor has potential applications for the analysis of benzene in workplace air samples, with the added advantages over the conventional GC methods of low operation costs, ease of use, and portability for in situ measurements.
Similar articles
-
Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process. Part I. A novel design of BOD biosensor for easy renewal of bio-receptor.Biosens Bioelectron. 2004 Oct 15;20(3):562-70. doi: 10.1016/j.bios.2004.03.008. Biosens Bioelectron. 2004. PMID: 15494240
-
Pseudomonas putida based amperometric biosensors for 2,4-D detection.Prep Biochem Biotechnol. 2009;39(1):11-9. doi: 10.1080/10826060802589460. Prep Biochem Biotechnol. 2009. PMID: 19090417
-
Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process; Part II: instrumentation of integrated flow injection analysis (FIA) system for BODst estimation.Biosens Bioelectron. 2004 Oct 15;20(3):571-8. doi: 10.1016/j.bios.2004.03.007. Biosens Bioelectron. 2004. PMID: 15494241
-
Microchip capillary electrophoresis.Methods Mol Biol. 2009;509:159-68. doi: 10.1007/978-1-59745-372-1_11. Methods Mol Biol. 2009. PMID: 19212721 Review.
-
Ethanol biosensors based on alcohol oxidase.Biosens Bioelectron. 2005 Aug 15;21(2):235-47. doi: 10.1016/j.bios.2004.09.030. Epub 2004 Dec 7. Biosens Bioelectron. 2005. PMID: 16023950 Review.
Cited by
-
High Sensitivity Monitoring of VOCs in Air through FTIR Spectroscopy Using a Multipass Gas Cell Setup.Sensors (Basel). 2022 Jul 27;22(15):5624. doi: 10.3390/s22155624. Sensors (Basel). 2022. PMID: 35957181 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous