Visual acuity measurements using Fourier series harmonic analysis of videokeratography data in eyes after penetrating keratoplasty
- PMID: 15745768
- DOI: 10.1016/j.ophtha.2004.09.026
Visual acuity measurements using Fourier series harmonic analysis of videokeratography data in eyes after penetrating keratoplasty
Abstract
Purpose: Fourier harmonic analysis can decompose videokeratography data into spherical power, regular astigmatism, and irregular astigmatism (asymmetry and higher-order irregularity). The aim of this study was to evaluate whether determination of cylinder power by Fourier analysis facilitates measurements of visual acuity and refraction in eyes after penetrating keratoplasty.
Design: Cross-sectional study.
Participants: Sixty-six eyes of 56 subjects who had undergone penetrating keratoplasty.
Methods: Spectacle-corrected visual acuity was measured in 2 ways: by the conventional and the Fourier methods. In the conventional method, the refraction was determined subjectively by reference to the measurement results of the autokeratometer and autorefractometer. In the Fourier method, the magnitude and axis of regular astigmatism were calculated by Fourier analysis of the videokeratography data, and spherical lenses were adjusted until best spectacle-corrected visual acuity was attained.
Main outcome measures: Logarithm of the minimum angle of resolution (logMAR) visual acuity and refraction used for correction.
Results: The spectacle-corrected visual acuity obtained with the Fourier method (logMAR, 0.23+/-0.32; Snellen equivalent, 20/34) was significantly better than that attained with the conventional method (logMAR, 0.31+/-0.29; Snellen equivalent, 20/41; P<0.001, paired t test). The cylinder power used for spectacle-corrected visual acuity measurements was significantly lower with the Fourier method (-2.41+/-1.26 diopters [D]) than with the conventional method (-3.53+/-1.64 D; P<0.001). The spherical equivalent at the final refraction was not different between groups (P = 0.207).
Conclusions: Fourier analysis of videokeratography data significantly facilitates determination of refraction and measurement of best spectacle-corrected visual acuity in eyes with corneal irregular astigmatism, such as eyes that have undergone penetrating keratoplasty.
Similar articles
-
Long-term changes in corneal surface configuration after penetrating keratoplasty.Am J Ophthalmol. 2006 Feb;141(2):241-247. doi: 10.1016/j.ajo.2005.08.062. Am J Ophthalmol. 2006. PMID: 16458675
-
Quantitative evaluation of irregular astigmatism by fourier series harmonic analysis of videokeratography data.Invest Ophthalmol Vis Sci. 1998 Apr;39(5):705-9. Invest Ophthalmol Vis Sci. 1998. PMID: 9538876
-
Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes.Ophthalmology. 2004 Apr;111(4):752-7. doi: 10.1016/j.ophtha.2003.06.019. Ophthalmology. 2004. PMID: 15051209
-
[Quantitative assessment of quality of vision].Nippon Ganka Gakkai Zasshi. 2004 Dec;108(12):770-807; discussion 808. Nippon Ganka Gakkai Zasshi. 2004. PMID: 15656087 Review. Japanese.
-
[Results of transverse incisions in surgical correction of severe post-keratoplasty astigmatism].J Fr Ophtalmol. 1990;13(10):492-9. J Fr Ophtalmol. 1990. PMID: 2081839 Review. French.
Cited by
-
Corneal topography in keratoconus evaluated more than 30 years after penetrating keratoplasty: a Fourier harmonic analysis.Sci Rep. 2020 Sep 10;10(1):14880. doi: 10.1038/s41598-020-71818-w. Sci Rep. 2020. PMID: 32913233 Free PMC article.
-
Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography.Sci Rep. 2022 Oct 25;12(1):17865. doi: 10.1038/s41598-022-22144-w. Sci Rep. 2022. PMID: 36284222 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical