Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes
- PMID: 15752908
- DOI: 10.1016/j.ijrobp.2004.11.033
Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes
Abstract
Purpose: Recent imaging studies have demonstrated that there can be significant changes in anatomy from day to day and over the course of radiotherapy as a result of daily positioning uncertainties and physiologic and clinical factors. There are a number of strategies to minimize such changes, reduce their impact, or correct for them. Measures to date have included improved immobilization of external and internal anatomy or adjustment of positions based on portal or ultrasound images. Perhaps the most accurate way is to use CT image-guided radiotherapy, for which the possibilities range from simple correction of setup based on daily CT images to on-line near real-time intensity modulated radiotherapy (IMRT) replanning. In addition, there are numerous intermediate possibilities. In this paper, we report the development of one such intermediate method that takes into account anatomic changes by deforming the intensity distributions of each beam based on deformations of anatomy as seen in the beam's-eye-view.
Methods and materials: The intensity distribution deformations are computed based on anatomy deformations discerned from the changes in the current image relative to a reference image (e.g., the pretreatment CT scan). First, a reference IMRT plan is generated based on the reference CT image. A new CT image is acquired using an in-room CT for every fraction. The anatomic structure contours are obtained for the new image. (For this article, these contours were manually drawn. When image guided IMRT methods are implemented, anatomic structure contours on subsequent images will likely be obtained with automatic or semiautomatic means. This could be achieved by, for example, first deforming the original CT image to match today's image, and then using the same deformation transformation to map original contours to today's image.) The reference intensity distributions for each beam are then deformed so that the projected geometric relationship within the beam's-eye-view between the anatomy (both target and normal tissues) extracted from the reference image and the reference intensity distribution is the same as (or as close as possible to) the corresponding relationship between anatomy derived from today's image and the newly deformed intensity distributions. To verify whether the dose distributions calculated using the deformed intensity distributions are acceptable for treatment as compared to the original intensity distributions, the deformed intensities are transformed into leaf sequences, which are then used to compute intensity and dose distributions expected to be delivered. The corresponding dose-volume histograms and dose-volume and dose-response indices are also computed. These data are compared with the corresponding data derived (a) from the original treatment plan applied to the original image, (b) from the original treatment plan applied to today's image, and (c) from a new full-fledged IMRT plan designed based on today's image.
Results: Depending on the degree of anatomic changes, the use of an IMRT plan designed based on the original planning CT for the treatment of the current fraction could lead to significant differences compared to the intended dose distributions. CT-guided setup compared to the setup based on skin marks or bony landmarks may improve dose distributions somewhat. Replanning IMRT based on the current fraction's image yields the best physically deliverable plan (the "gold standard"). For the prostate and head-and-neck examples studied as proof of principle, the results of deforming intensities within each beam based on the anatomy seen in the beam's-eye-view are a good approximation of full-fledged replanning compared with other alternatives.
Conclusions: Our preliminary results encourage us to believe that deforming intensities taking into account deformation in the anatomy may be a rapid way to produce new treatment plans on-line in near real-time based on daily CT images. The methods we have developed need to be applied to a group of patients for both prostate and head-and-neck cases to confirm the validity of our approach.
Similar articles
-
A cone beam CT-guided online plan modification technique to correct interfractional anatomic changes for prostate cancer IMRT treatment.Phys Med Biol. 2009 Mar 21;54(6):1691-703. doi: 10.1088/0031-9155/54/6/019. Epub 2009 Feb 25. Phys Med Biol. 2009. PMID: 19242051
-
MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT.Int J Radiat Oncol Biol Phys. 2004 Oct 1;60(2):636-47. doi: 10.1016/j.ijrobp.2004.05.068. Int J Radiat Oncol Biol Phys. 2004. PMID: 15380601
-
Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy.Med Phys. 2014 Mar;41(3):031710. doi: 10.1118/1.4866222. Med Phys. 2014. PMID: 24593714
-
Dose to normal tissues outside the radiation therapy patient's treated volume: a review of different radiation therapy techniques.Health Phys. 2008 Nov;95(5):666-76. doi: 10.1097/01.HP.0000326342.47348.06. Health Phys. 2008. PMID: 18849701 Review.
-
Comparison of three-dimensional conformal radiation therapy and intensity-modulated radiation therapy systems.Semin Radiat Oncol. 1999 Jan;9(1):78-98. doi: 10.1016/s1053-4296(99)80056-3. Semin Radiat Oncol. 1999. PMID: 10196400 Review.
Cited by
-
On-line adaptive radiation therapy: feasibility and clinical study.J Oncol. 2010;2010:407236. doi: 10.1155/2010/407236. Epub 2010 Nov 22. J Oncol. 2010. PMID: 21113304 Free PMC article.
-
Review of cone beam computed tomography based online adaptive radiotherapy: current trend and future direction.Radiat Oncol. 2023 Sep 2;18(1):144. doi: 10.1186/s13014-023-02340-2. Radiat Oncol. 2023. PMID: 37660057 Free PMC article. Review.
-
Adaptive radiotherapy for NSCLC patients: utilizing the principle of energy conservation to evaluate dose mapping operations.Phys Med Biol. 2017 Jun 7;62(11):4333-4345. doi: 10.1088/1361-6560/aa54a5. Epub 2017 May 5. Phys Med Biol. 2017. PMID: 28475493 Free PMC article.
-
[Translational uroradio-oncology].Urologe A. 2013 Sep;52(9):1276-82. doi: 10.1007/s00120-013-3314-2. Urologe A. 2013. PMID: 24026061 German.
-
Towards automated on-line adaptation of 2-Step IMRT plans: QUASIMODO phantom and prostate cancer cases.Radiat Oncol. 2013 Nov 8;8:263. doi: 10.1186/1748-717X-8-263. Radiat Oncol. 2013. PMID: 24207129 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical