Model selection in spatio-temporal electromagnetic source analysis
- PMID: 15759571
- DOI: 10.1109/TBME.2004.842982
Model selection in spatio-temporal electromagnetic source analysis
Abstract
Several methods [model selection procedures (MSPs)] to determine the number of sources in electroencephalogram (EEG) and magnetoencphalogram (MEG) data have previously been investigated in an instantaneous analysis. In this paper, these MSPs are extended to a spatio-temporal analysis if possible. It is seen that the residual variance (RV) tends to overestimate the number of sources. The Akaike information criterion (AIC) and the Wald test on amplitudes (WA) and the Wald test on locations (WL) have the highest probabilities of selecting the correct number of sources. The WA has the advantage that it offers the opportunity to test which source is active at which time sample.
Similar articles
-
Model selection in electromagnetic source analysis with an application to VEFs.IEEE Trans Biomed Eng. 2002 Oct;49(10):1121-9. doi: 10.1109/TBME.2002.803543. IEEE Trans Biomed Eng. 2002. PMID: 12374336
-
Distinguishing between moving and stationary sources using EEG/MEG measurements with an application to epilepsy.IEEE Trans Biomed Eng. 2005 Mar;52(3):471-9. doi: 10.1109/TBME.2004.843289. IEEE Trans Biomed Eng. 2005. PMID: 15759577 Clinical Trial.
-
Anatomically constrained dipole adjustment (ANACONDA) for accurate MEG/EEG focal source localizations.Phys Med Biol. 2005 Oct 21;50(20):4931-53. doi: 10.1088/0031-9155/50/20/012. Epub 2005 Oct 4. Phys Med Biol. 2005. PMID: 16204881
-
Mapping human brain function with MEG and EEG: methods and validation.Neuroimage. 2004;23 Suppl 1:S289-99. doi: 10.1016/j.neuroimage.2004.07.014. Neuroimage. 2004. PMID: 15501098 Review.
-
Functional localization of brain sources using EEG and/or MEG data: volume conductor and source models.Magn Reson Imaging. 2004 Dec;22(10):1533-8. doi: 10.1016/j.mri.2004.10.010. Magn Reson Imaging. 2004. PMID: 15707802 Review.
Cited by
-
Activated region fitting: a robust high-power method for fMRI analysis using parameterized regions of activation.Hum Brain Mapp. 2009 Aug;30(8):2595-605. doi: 10.1002/hbm.20697. Hum Brain Mapp. 2009. PMID: 19172652 Free PMC article.
-
Spatio-temporal Bayesian model selection for disease mapping.Environmetrics. 2016 Dec;27(8):466-478. doi: 10.1002/env.2410. Epub 2016 Sep 28. Environmetrics. 2016. PMID: 28070156 Free PMC article.
-
The distressed brain: a group blind source separation analysis on tinnitus.PLoS One. 2011;6(10):e24273. doi: 10.1371/journal.pone.0024273. Epub 2011 Oct 6. PLoS One. 2011. PMID: 21998628 Free PMC article.
-
Estimation of number of independent brain electric sources from the scalp EEGs.IEEE Trans Biomed Eng. 2006 Oct;53(10):1883-92. doi: 10.1109/TBME.2006.876620. IEEE Trans Biomed Eng. 2006. PMID: 17019851 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources