Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 May;320(2):229-34.
doi: 10.1007/s00441-004-1031-2. Epub 2005 Mar 11.

Investigating the mechanical shear-plane between core and sheath elements of peripheral nerves

Affiliations

Investigating the mechanical shear-plane between core and sheath elements of peripheral nerves

G A Georgeu et al. Cell Tissue Res. 2005 May.

Abstract

The mechanical architecture of rat sciatic nerve has been described as a central core surrounded by a sheath, although the way in which these structures contribute to the overall mechanical properties of the nerve is unknown. We have studied the retraction responses of the core and sheath following transection, together with their tensile properties and the interface between them. Nerves were harvested and maintained at their in situ tension and then either transected entirely, through the sheath only, or through an exposed section of the core. The retraction of each component was measured within 5 min and again after 45 min. Post mortem loss of retraction was tested 0 min or 60 min after excision. For fresh nerves, immediate retraction was 12.68% (whole nerve), 5.35% (sheath) and 4% (core), with a total retraction of 15%, 7.21% and 5.26% respectively. For stored nerves, immediate retraction was 5.33% (whole nerve) and 5.87% (sheath), with an extension of 0.78% for core, and a total retraction of 6.71% and 7.87% and an extension of 1.74%, respectively. Tensile extension and pullout force profiles were obtained for the sheath, the core and the interface between them. These showed a consistent hierarchy of break strengths that would, under increasing load, result in failure of the interface, then the core and finally the sheath. These data reflect the contributions of material tension and fluid swelling pressure to total retraction, and the involvement of an energy-dependent process that runs down rapidly post mortem. This study increases our understanding of the composite nature of peripheral nerve tissue architecture and quantifies the material properties of the distinct elements that contribute to overall mechanical function.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources