[Three-dimensional finite element analysis of the biomechanical effects of multiloop edgewise archwire (MEAW)]
- PMID: 15762123
[Three-dimensional finite element analysis of the biomechanical effects of multiloop edgewise archwire (MEAW)]
Abstract
This study is designed to theoretically evaluate the treatment effects of MEAW with tip back bends on the mandible dentition when used as a finishing archwire without elastic and with long class III elastics respectively, and to compare them with those of stainless-steel wire and shape-memory wire. The finite element analysis (FEA) method was adopted and the findings were as follows: (1) In the case of no elastics, the MEAW rotates the second premolar, the first molar and the second molar distally while rotating other teeth mesially, and depresses anterior teeth. However, the stainless-steel wire and the shape-memory wire rotate molars distally while rotating other teeth mesially. Furthermore, they extrude anterior teeth and depress posterior teeth. (2) The MEAW with tip back bends and long class III elastics inclines and rotates posterior teeth more distally than the MEAW with only tip back bends does. In the case of tip back bends and long class III elastics loaded together, the shape-memory wire inclines teeth in greater strength as compared with the stainless-steel wire. (3) The stress level of tooth root is the lowest with MEAW, the highest with stainless-steel wire, and is middle with the shape-memory wire. From these results, it is suggested that: (1) The MEAW therapy technique is effective for leveling the curve of Spee and regulating tooth respectively. (2) The MEAW therapy technique can transfer therapy force efficiently. (3) The MEAW is considered to be suitable for treating openbite malocclusion to make the posterior teeth upright because it effectively rotates teeth distally through the force of posterior bends and long class III elastics. (4) The loaded force on the teeth is more soft and permanent in the MEAW than in the stainless-steel wire and the shape-memory wire.
Similar articles
-
Initial effect of multiloop edgewise archwire on the mandibular dentition in Class III malocclusion subjects. A three-dimensional finite element study.Eur J Orthod. 2008 Feb;30(1):10-5. doi: 10.1093/ejo/cjm098. Eur J Orthod. 2008. PMID: 18276927
-
Three-dimensional finite element analysis in distal en masse movement of the maxillary dentition with the multiloop edgewise archwire.Eur J Orthod. 2004 Jun;26(3):339-45. doi: 10.1093/ejo/26.3.339. Eur J Orthod. 2004. PMID: 15222721
-
Camouflage treatment of skeletal Class III malocclusion with multiloop edgewise arch wire and modified Class III elastics by maxillary mini-implant anchorage.Angle Orthod. 2013 Jul;83(4):630-40. doi: 10.2319/091312-730.1. Epub 2013 Jan 11. Angle Orthod. 2013. PMID: 23311602 Free PMC article.
-
An alternative approach to distalizing a maxillary molar: case report.J Clin Pediatr Dent. 1997 Winter;21(2):105-7. J Clin Pediatr Dent. 1997. PMID: 9484100 Review.
-
Multiloop edgewise archwire technique and denture frame analysis: a systematic review.Head Face Med. 2020 Nov 26;16(1):32. doi: 10.1186/s13005-020-00247-x. Head Face Med. 2020. PMID: 33243257 Free PMC article.