Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Apr;75(2):105-13.
doi: 10.1016/j.jenvman.2004.11.009.

Preservative leaching from weathered CCA-treated wood

Affiliations

Preservative leaching from weathered CCA-treated wood

Timothy Townsend et al. J Environ Manage. 2005 Apr.

Abstract

Disposal of discarded chromated copper arsenate (CCA)-treated wood in landfills raises concerns with respect to leaching of preservative compounds. When unweathered CCA-treated wood is leached using the toxicity characteristic leaching procedure (TCLP), arsenic concentrations exceed the toxicity characteristic (TC) limit of 5mg/L in most cases. The majority of discarded CCA-treated wood, however, results from demolition activities, where the wood has typically been subjected to weathering. Since preservatives do migrate from the wood during its normal use, leaching characteristics of weathered and aged CCA-treated wood may differ from unweathered wood. To evaluate this, CCA-treated wood removed from service after various degrees of weathering was collected from multiple sources and leached with the TCLP, the synthetic precipitation leaching procedure (SPLP) and California's waste extraction test (WET). Five to seven individual pieces of wood were analyzed from each source. The average TCLP arsenic concentration for the 14 sources ranged from 3.2 to 13 mg/L. The average TCLP concentrations of the 100 wood pieces tested were 6.4, 5.9 and 3.2 mg/L for arsenic, copper and chromium, respectively. Overall, in 60 out of 100 samples tested by the TCLP, arsenic concentrations exceeded 5 mg/L (the TC regulatory value). SPLP leachate concentrations were similar to TCLP concentrations, although copper leached somewhat more with the TCLP. WET leachate concentrations were approximately a factor of 10 higher than TCLP concentrations. Discarded CCA-treated wood, even after exposure to years of weathering, often exceeds the TC limit for arsenic and without the current regulatory exemption would possibly require management as a TC hazardous waste in the US.

PubMed Disclaimer

Publication types

LinkOut - more resources