Optical coherence tomography assessment of capsule closure after cataract surgery
- PMID: 15767154
- DOI: 10.1016/j.jcrs.2004.04.057
Optical coherence tomography assessment of capsule closure after cataract surgery
Abstract
Purpose: To develop a technique for documenting and quantifying capsule bend formation in pseudophakic eyes, evaluate when the anterior and posterior lens capsules become completely apposed to the optic, and determine how soon a capsule bend is created at the optic edge of an intraocular lens (IOL) after cataract surgery.
Setting: Medical University of Vienna, Department of Ophthalmology, Vienna, Austria.
Methods: This prospective study comprised 33 eyes of 33 patients with age-related cataract who were scheduled to have cataract surgery. All eyes had phacoemulsification with implantation of 1 of 3 types of open-loop IOLs: 1-piece acrylic (SA60AT, Alcon), 3-piece acrylic (AcrySof MA60BM, Alcon), or 3-piece silicone (911A, AMO). Each group included 11 eyes. One and 3 days and 1, 2, 3, and 4 weeks after surgery, contact between the lens capsule and IOL optic as well as capsule bend formation were evaluated using optical coherence tomography (OCT). The postoperative times at which the capsule came into contact with the IOL optic and when the capsule bend formed were determined.
Results: One day postoperatively, the mean distance between the anterior capsule and the IOL was 197 microm in the 1-piece acrylic IOL group, 161 microm in the 3-piece acrylic IOL group, and 220 microm in the 3-piece silicone IOL group. The posterior capsule was in contact with the IOL on the same day or earlier than the anterior capsule in 28 patients (85%). Postoperatively, the capsule bend formed at a mean of 10 days in the 1-piece acrylic group, 13 days in the 3-piece acrylic group, and 15 days in the 3-piece silicone group. The short-term reproducibility of the OCT technique was excellent (r = 0.99).
Conclusions: Optical coherence tomography produced cross-sectional tomograms of capsule-IOL contact in the early postoperative period. There was no significant difference in the time to capsule bend formation between the 3 IOLs. However, capsule bend formation at the optic edge occurred earlier with the 1-piece acrylic IOL than with the 3-piece silicone IOL.
Similar articles
-
Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction.J Cataract Refract Surg. 2004 Sep;30(9):1875-82. doi: 10.1016/j.jcrs.2004.01.042. J Cataract Refract Surg. 2004. PMID: 15342049 Clinical Trial.
-
Intraocular lens factors that may affect anterior capsule contraction.Ophthalmology. 2005 Feb;112(2):286-92. doi: 10.1016/j.ophtha.2004.11.013. Ophthalmology. 2005. PMID: 15691565 Clinical Trial.
-
Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery.J Cataract Refract Surg. 2009 Mar;35(3):459-65. doi: 10.1016/j.jcrs.2008.11.044. J Cataract Refract Surg. 2009. PMID: 19251138
-
Incision sizes before and after implantation of 6-mm optic foldable intraocular lenses using Monarch and Unfolder injector systems.Ophthalmology. 2005 Jan;112(1):58-66. doi: 10.1016/j.ophtha.2004.06.030. Ophthalmology. 2005. PMID: 15629821 Review.
-
Negative dysphotopsia: A perfect storm.J Cataract Refract Surg. 2015 Oct;41(10):2291-312. doi: 10.1016/j.jcrs.2015.09.002. J Cataract Refract Surg. 2015. PMID: 26703307 Review.
Cited by
-
[Influence of intraocular lens material and design on the development of posterior capsule opacification].Ophthalmologe. 2005 Jun;102(6):572-8. doi: 10.1007/s00347-005-1222-6. Ophthalmologe. 2005. PMID: 15895236 German.
-
The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography.PLoS One. 2015 Nov 23;10(11):e0142556. doi: 10.1371/journal.pone.0142556. eCollection 2015. PLoS One. 2015. PMID: 26600254 Free PMC article.
-
Macular thickness after uneventful cataract surgery determined by optical coherence tomography.Graefes Arch Clin Exp Ophthalmol. 2007 Dec;245(12):1765-71. doi: 10.1007/s00417-007-0605-6. Epub 2007 Jul 10. Graefes Arch Clin Exp Ophthalmol. 2007. PMID: 17619896
-
An Optical Section-Assisted In Vivo Rabbit Model for Capsular Bend and Posterior Capsule Opacification Investigation.PLoS One. 2016 Feb 3;11(2):e0148553. doi: 10.1371/journal.pone.0148553. eCollection 2016. PLoS One. 2016. PMID: 26840405 Free PMC article.
-
Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.PLoS One. 2017 Sep 1;12(9):e0184066. doi: 10.1371/journal.pone.0184066. eCollection 2017. PLoS One. 2017. PMID: 28863141 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical