Cross-contamination in the dental laboratory through the polishing procedure of complete dentures
- PMID: 15776197
- DOI: 10.1590/s0103-64402004000200010
Cross-contamination in the dental laboratory through the polishing procedure of complete dentures
Abstract
Polishing of dental prostheses can cause a dangerous cycle of cross-contamination involving dentists, laboratory technicians, patients and auxiliary personnel. The aim of this study was to show the microbial contamination in the dental laboratory during the polishing procedure of complete dentures. For this purpose, 4 experiments were conducted. Experiment I -- Determination of the total colony-forming units (CFU) counts contaminating complete maxillary dentures. During the polishing procedure, determination of the CFU counts transferred to the operator (Experiment II) and of the total CFU counts transferred to previously sterilized complete dentures (Experiment III). Experiment IV -- The total counts of remaining CFU in the lathe spindle after Experiments II and III. Complete dentures were highly contaminated (mean = 1.4 x 10(7) CFU/mL). There was a elevated level of contamination by splatter and aerosols. There was high microbial transfer from the contaminated lathe spindle to the sterile prostheses (mean = 1.7 x 10(7) CFU/mL). The spindles were highly contaminated after polishing procedures (mean = 3.5 x 10(8) CFU/mL). The polishing of dental prostheses is a possible source of transmission of communicable diseases in the laboratory and requires improved techniques for infection control.
Similar articles
-
Microbiological hazard analysis in dental technology laboratories.Eur J Prosthodont Restor Dent. 2004 Sep;12(3):115-20. Eur J Prosthodont Restor Dent. 2004. PMID: 15521394
-
Practical infection control in dental laboratories.Gen Dent. 1994 Nov-Dec;42(6):545-8. Gen Dent. 1994. PMID: 23087983
-
Clinical quality of removable dentures provided by dentists, denturists and laboratory technicians.J Oral Rehabil. 2003 Apr;30(4):347-52. doi: 10.1046/j.1365-2842.2003.01055.x. J Oral Rehabil. 2003. PMID: 12631157
-
Microbial contamination of dental unit waterlines.Ann Agric Environ Med. 2008;15(2):173-9. Ann Agric Environ Med. 2008. PMID: 19061251 Review.
-
Do contaminated dental unit waterlines pose a risk of infection?J Dent. 2007 Sep;35(9):712-20. doi: 10.1016/j.jdent.2007.06.002. Epub 2007 Aug 6. J Dent. 2007. PMID: 17689168 Review.
Cited by
-
Quantitative Analysis of Selected Microorganisms Present at Various Sites in a Prosthetics Clinic and Dental Laboratory during Complete Denture Fabrication.Int J Environ Res Public Health. 2020 May 12;17(10):3345. doi: 10.3390/ijerph17103345. Int J Environ Res Public Health. 2020. PMID: 32408512 Free PMC article.
-
Workplace determinants of endotoxin exposure in dental healthcare facilities in South Africa.Ann Occup Hyg. 2010 Apr;54(3):299-308. doi: 10.1093/annhyg/mep095. Epub 2009 Dec 31. Ann Occup Hyg. 2010. PMID: 20044586 Free PMC article.
-
Evaluation of Surface Microhardness Following Chemical and Microwave Disinfection of Commercially Available Acrylic Resin Denture Teeth.J Clin Diagn Res. 2017 May;11(5):ZC87-ZC91. doi: 10.7860/JCDR/2017/27587.9944. Epub 2017 May 1. J Clin Diagn Res. 2017. PMID: 28658916 Free PMC article.
-
Infection control awareness level among dental laboratory technicians, Riyadh, Saudi Arabia.J Family Med Prim Care. 2021 Apr;10(4):1540-1546. doi: 10.4103/jfmpc.jfmpc_2258_20. Epub 2021 Apr 29. J Family Med Prim Care. 2021. PMID: 34123889 Free PMC article. Review.
-
Uniform-related infection control practices of dental students.Infect Drug Resist. 2017 Apr 24;10:135-142. doi: 10.2147/IDR.S128161. eCollection 2017. Infect Drug Resist. 2017. PMID: 28490894 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources