Purpose: The corneal horizontal diameter (white-to-white) is abnormal in diseases like microcornea, relative anterior microphthalmos, and corneal dystrophies. Because normal values are described imprecisely in the literature, the purpose of this study was to reevaluate the horizontal corneal diameter as a scientific parameter.
Methods: The horizontal corneal diameter was measured with the Orbscan II system in 370 right eyes and 373 left eyes of 390 healthy white subjects aged 10-80 years. There were 148 female subjects and 242 male subjects. Each measurement was repeated twice. Differences in gender, between right and left eyes, and age-related alterations were analyzed statistically.
Results: The average corneal diameter was 11.71 +/- 0.42 mm. The average corneal diameter was 11.77 +/- 0.37 mm in males compared with 11.64 +/- 0.47 mm in females. The resulting normal ranges were 11.04 to 12.50 for males and 10.70 to 12.58 mm for females. Differences in gender were not significant in the t test for independent samples (P = 0.071). There were no statistically significant differences between right and left eyes in the t test for dependent samples (P = 0.16). Corneal diameters decreased slightly with age.
Conclusions: With the obtained normal values, more precise determination of microcornea and macrocornea will be possible in the future. The horizontal corneal diameter was not significantly greater in males than in females. Further studies are needed to show the reasons for the age-related decrease in measurements.
Similar articles
-
Age-related changes in central and peripheral corneal thickness: determination of normal values with the Orbscan II topography system.Cornea. 2007 Jan;26(1):1-5. doi: 10.1097/01.ico.0000240095.95067.3f. Cornea. 2007. PMID: 17198005
-
White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II.Int J Ophthalmol. 2014 Apr 18;7(2):309-12. doi: 10.3980/j.issn.2222-3959.2014.02.20. eCollection 2014. Int J Ophthalmol. 2014. PMID: 24790875 Free PMC article.
-
Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systems.Clin Exp Optom. 2009 Sep;92(5):429-33. doi: 10.1111/j.1444-0938.2009.00407.x. Epub 2009 Jul 21. Clin Exp Optom. 2009. PMID: 19681922
-
White-to-white corneal diameter in the Tehran Eye Study.Cornea. 2010 Jan;29(1):9-12. doi: 10.1097/ICO.0b013e3181a9d0a9. Cornea. 2010. PMID: 19907300
-
[A review of mathematical descriptors of corneal asphericity].J Fr Ophtalmol. 2002 Jan;25(1):81-90. J Fr Ophtalmol. 2002. PMID: 11965125 Review. French.
Cited by
-
Corneal white-to-white distance and mesopic pupil diameter.Int J Ophthalmol. 2012;5(4):505-9. doi: 10.3980/j.issn.2222-3959.2012.04.19. Epub 2012 Aug 18. Int J Ophthalmol. 2012. PMID: 22937514 Free PMC article.
-
Distribution of White-to-White Corneal Diameter and Anterior Chamber Depth in Chinese Myopic Patients.Front Med (Lausanne). 2021 Nov 18;8:732719. doi: 10.3389/fmed.2021.732719. eCollection 2021. Front Med (Lausanne). 2021. PMID: 34869427 Free PMC article.
-
Cellular and extracellular matrix modulation of corneal stromal opacity.Exp Eye Res. 2014 Dec;129:151-60. doi: 10.1016/j.exer.2014.09.013. Epub 2014 Oct 1. Exp Eye Res. 2014. PMID: 25281830 Free PMC article. Review.
-
Anterior approach white line advancement: technique and long-term outcomes in the correction of blepharoptosis.Eye (Lond). 2017 Dec;31(12):1716-1723. doi: 10.1038/eye.2017.138. Epub 2017 Aug 11. Eye (Lond). 2017. PMID: 28799556 Free PMC article.
-
Periorbital facial rejuvenation; applied anatomy and pre-operative assessment.J Curr Ophthalmol. 2017 Apr 25;29(3):154-168. doi: 10.1016/j.joco.2017.04.001. eCollection 2017 Sep. J Curr Ophthalmol. 2017. PMID: 28913505 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical