. 2005 Mar 20;118(6):446-50.

Evaluation by indirect immunofluorescent assay and enzyme linked immunosorbent assay of the dynamic changes of serum antibody responses against severe acute respiratory syndrome coronavirus

Affiliations
  • PMID: 15788124

Evaluation by indirect immunofluorescent assay and enzyme linked immunosorbent assay of the dynamic changes of serum antibody responses against severe acute respiratory syndrome coronavirus

Hong-ying Mo et al. Chin Med J (Engl). .

Abstract

Background: Severe acute respiratory syndrome coronavirus (SARS-CoV) is a newly emerging virus that gives rise to SARS patients with high rates of infectivity and fatality. To study the humoral immune responses to SARS-CoV, the authors evaluated IgG and IgM specific antibodies in patients' sera.

Methods: Two methods, enzyme-linked immunosorbent assay (ELISA) and indirect immunofluorescent assay (IFA), were used to detect specific serum IgG and IgM against SARS-CoV in 98 SARS patients and 250 controls consisting of patients with pneumonia, health-care professionals and healthy subjects. The serum antibody profiles were investigated at different times over one and a half years in 18 of the SARS patients.

Results: The sensitivity and specificity of ELISA for detecting IgG against SARS-CoV were 100.0% and 97.2% and for IgM 89.8% and 97.6% respectively; the figures using IFA for IgG were 100.0% and 100.0% and for IgM 81.8% and 100.0% respectively. During the first seven days of the antibodies trace test, no IgG and IgM were detected, but on day 15, IgG response increased dramatically, reaching a peak on day 60, remaining high up to day 180 and decreasing gradually until day 540. On day 15, IgM was detected, rapidly reached a peak, then declined gradually until day 180 when IgM was undetectable.

Conclusion: The detection of antibodies against SARS virus is helpful in the clinical diagnosis of SARS.