[Low flip angle spin-echo MR imaging to obtain better Gd-DTPA enhanced imaging with ECG gating]
- PMID: 1579428
[Low flip angle spin-echo MR imaging to obtain better Gd-DTPA enhanced imaging with ECG gating]
Abstract
ECG-gated spin-echo imaging (ECG-SE) can reduce physiological motion artifacts. However, ECG-SE does not provide strong T1-weighted images because repetition time (TR) depends on heart rate (HR). We investigated the usefulness of low flip angle spin-echo imaging (LFSE) in obtaining more T1-dependent contrast with ECG gating. in computer simulation, the predicted image contrast and signal-to-noise ratio (SNR) obtained for each flip angle (0-180 degrees) and each TR (300 msec-1200 msec) were compared with those obtained by conventional T1-weighted spin-echo imaging (CSE: TR = 500 msec, TE = 20 msec). In clinical evaluation, tissue contrast [contrast index (CI): (SI of lesion-SI of muscle)2*100/SI of muscle] obtained by CSE and LFSE were compared in 17 patients. At a TR of 1,000 msec, T1-dependent contrast increased with decreasing flip angle and that at 38 degrees was identical to that with T1-weighted spin-echo. SNR increased with the flip angle until 100 degrees, and that at 53 degrees was identical to that with T1-weighted spin-echo. CI on LFSE (74.0 +/- 52.0) was significantly higher than CI on CSE (40.9 +/- 35.9). ECG-gated LFSE imaging provides better T1-dependent contrast than conventional ECG-SE. This method was especially useful for Gd-DTPA enhanced MR imaging.
Similar articles
-
T1-weighted images with ECG gating using partial flip angle spin-echo imaging.Clin Radiol. 1994 Dec;49(12):871-3. doi: 10.1016/s0009-9260(05)82878-8. Clin Radiol. 1994. PMID: 7828394
-
[Low flip-angle spin-echo imaging of the liver. Basic study and its application to hepatic space-occupying lesions].Nihon Igaku Hoshasen Gakkai Zasshi. 1991 Sep 25;51(9):1017-26. Nihon Igaku Hoshasen Gakkai Zasshi. 1991. PMID: 1658732 Japanese.
-
3D MRI of the cervical spine: low flip angle FISP vs. Gd-DTPA TurboFLASH in degenerative disk disease.J Comput Assist Tomogr. 1993 Jan-Feb;17(1):26-33. J Comput Assist Tomogr. 1993. PMID: 8419435
-
Quality of clinical MR images and the use of contrast agents.Radiographics. 1995 May;15(3):683-96. doi: 10.1148/radiographics.15.3.7624572. Radiographics. 1995. PMID: 7624572 Review.
-
Advanced MR imaging techniques for evaluation of the heart and great vessels.Radiographics. 1998 May-Jun;18(3):543-64. doi: 10.1148/radiographics.18.3.9599382. Radiographics. 1998. PMID: 9599382 Review.
Cited by
-
Enhancing gray-to-white matter contrast in 3T T1 spin-echo brain scans by optimizing flip angle.AJNR Am J Neuroradiol. 2005 Sep;26(8):2000-4. AJNR Am J Neuroradiol. 2005. PMID: 16155149 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical