Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector
- PMID: 15795836
Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector
Abstract
We evaluated a new 3D angiography system with a flat panel detector (FPD) for its capabilitiy to acquire volume sets during a single rotation scan and to reconstruct high spatial resolution three-dimensional and cross sectional images, namely cone beam volume computed tomography (CBVCT) images. Present status of the technique, advantages and potential applications are discussed.
Similar articles
-
Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation.IEEE Trans Med Imaging. 2000 Sep;19(9):949-63. doi: 10.1109/42.887842. IEEE Trans Med Imaging. 2000. PMID: 11127608
-
High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging.Phys Med Biol. 2011 Oct 7;56(19):6495-519. doi: 10.1088/0031-9155/56/19/020. Epub 2011 Sep 20. Phys Med Biol. 2011. PMID: 21934193
-
Tailored timing as a critical factor in CT angiography.AJR Am J Roentgenol. 1994 Apr;162(4):997-9. doi: 10.2214/ajr.162.4.8141036. AJR Am J Roentgenol. 1994. PMID: 8141036 No abstract available.
-
X-ray computed tomography.Phys Med Biol. 2006 Jul 7;51(13):R29-43. doi: 10.1088/0031-9155/51/13/R03. Epub 2006 Jun 20. Phys Med Biol. 2006. PMID: 16790909 Review.
-
MDCT and 3D CT angiography of splanchnic artery aneurysms.AJR Am J Roentgenol. 2007 Sep;189(3):641-7. doi: 10.2214/AJR.07.2210. AJR Am J Roentgenol. 2007. PMID: 17715112 Review.
Cited by
-
Transmedullary Venous Anastomoses: Anatomy and Angiographic Visualization Using Flat Panel Catheter Angiotomography.AJNR Am J Neuroradiol. 2015 Jul;36(7):1381-8. doi: 10.3174/ajnr.A4302. Epub 2015 May 7. AJNR Am J Neuroradiol. 2015. PMID: 25953764 Free PMC article.
-
CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions.Medicine (Baltimore). 2016 Aug;95(32):e4358. doi: 10.1097/MD.0000000000004358. Medicine (Baltimore). 2016. PMID: 27512846 Free PMC article.
-
Evaluation and Verification of Fast Computational Simulations of Stent-Graft Deployment in Endovascular Aneurysmal Repair.Front Med Technol. 2021 Jul 20;3:704806. doi: 10.3389/fmedt.2021.704806. eCollection 2021. Front Med Technol. 2021. PMID: 35047943 Free PMC article.
-
Laser-guided percutaneous kidney access with the Uro Dyna-CT: first experience of three-dimensional puncture planning with an ex vivo model.World J Urol. 2013 Oct;31(5):1147-51. doi: 10.1007/s00345-012-0847-8. Epub 2012 Mar 4. World J Urol. 2013. PMID: 22391646
-
Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: a pilot study in patients with acute symptoms of cerebral ischemia.AJNR Am J Neuroradiol. 2010 Sep;31(8):1462-9. doi: 10.3174/ajnr.A2083. Epub 2010 Apr 8. AJNR Am J Neuroradiol. 2010. PMID: 20378700 Free PMC article. Clinical Trial.