Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols
- PMID: 15798689
- DOI: 10.1016/j.prosdent.2005.01.010
Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols
Abstract
Statement of problem: Surface quality of cast metal is directly related to service performance under fatigue stress. Surface heterogeneities resulting from either finishing or polishing processes or by corrosive agents such as fluoridated solutions, can negatively affect fatigue life. Cast titanium frameworks are difficult to polish, and an accepted polishing protocol has not been established.
Purpose: This study evaluated and compared surface roughness of cast commercially pure titanium (CP Ti) and Ti-6Al-4V alloy submitted to conventional or electrolytic polishing, correlating the results with corrosion-fatigue strength testing performed in artificial fluoridated saliva. Specimens were also tested in air at room temperature to evaluate the effectiveness of the corrosion-fatigue test model.
Material and methods: For each metal, 40 dumb-bell-shaped rods, 2.3 mm in diameter at the central segment, were cast. Conventional polishing was performed on 20 specimens of each metal following the manufacturer's instructions. A source of continuous electrical current was used for electrolytic polishing of the other 20 specimens of each metal, which were immersed in an electrolytic solution containing 5% fluoridric acid, 35% nitric acid, and 60% distilled water. Surface roughness, Ra (microm), was measured with a profilometer, and fatigue tests were carried out with a universal testing machine using a load 30% lower than the 0.2% offset yield strength. After failure, the fractured surfaces were examined using scanning electron microscopy. Surface roughness means were analyzed with a 2-way analysis of variance and the Tukey multiple comparisons test (alpha=.05).
Results: Electrolytic polishing (0.24 +/- 0.05 microm) provided significantly (P <.05) lower surface roughness values than conventional polishing (0.32 +/- 0.06 microm). Regardless of the polishing protocol, surface roughness of Ti-6Al-4V alloy (0.25 +/- 0.06 microm) was significantly lower (P <.05) than that of CP Ti (0.31 +/- 0.05 microm), and the fluoridated environment did not influence fatigue performance. There was no correlation between fatigue performance and surface roughness.
Conclusion: Surface roughness of Ti-6Al-4V was significantly lower than that of CP Ti. For cast titanium frameworks, the electrolytic polishing regimen was found to be more effective than the manufacturer's polishing instructions with abrasives and rotary instruments. After polishing, differences in surface roughness values did not affect corrosion-fatigue performance.
Similar articles
-
Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments.J Prosthet Dent. 2000 Sep;84(3):274-9. doi: 10.1067/mpr.2000.108758. J Prosthet Dent. 2000. PMID: 11005899
-
Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining.J Prosthet Dent. 2002 Nov;88(5):467-72. doi: 10.1067/mpr.2002.128954. J Prosthet Dent. 2002. PMID: 12473994
-
Over-refractory casting technique as an alternative to one-piece multi-unit fixed partial denture frameworks.J Prosthet Dent. 2006 Mar;95(3):243-8. doi: 10.1016/j.prosdent.2006.01.001. J Prosthet Dent. 2006. PMID: 16543023
-
Evaluation of the polished surface characteristic of cobalt-chrome castings subsequent to various finishing and polishing techniques.Indian J Dent Res. 2001 Oct-Dec;12(4):222-8. Indian J Dent Res. 2001. PMID: 11987661 Review.
-
Comparative analysis of corrosion resistance between beta titanium and Ti-6Al-4V alloys: A systematic review.J Trace Elem Med Biol. 2020 Dec;62:126618. doi: 10.1016/j.jtemb.2020.126618. Epub 2020 Jul 9. J Trace Elem Med Biol. 2020. PMID: 32663743
Cited by
-
Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study.J Periodontal Implant Sci. 2012 Dec;42(6):217-23. doi: 10.5051/jpis.2012.42.6.217. Epub 2012 Dec 31. J Periodontal Implant Sci. 2012. Retraction in: J Periodontal Implant Sci. 2019 Feb 07;49(1):58. doi: 10.5051/jpis.2019.49.1.58. PMID: 23346465 Free PMC article. Retracted.
-
Finite element and biomechanical analysis of risk factors for implant failure during tension band plating.J Int Med Res. 2020 Nov;48(11):300060520972075. doi: 10.1177/0300060520972075. J Int Med Res. 2020. PMID: 33251889 Free PMC article.
-
Human Gingival Fibroblast Attachment to Smooth Titanium Disks with Different Surface Roughnesses.Biomimetics (Basel). 2022 Oct 14;7(4):164. doi: 10.3390/biomimetics7040164. Biomimetics (Basel). 2022. PMID: 36278721 Free PMC article.
-
Process Optimization of Polishing Titanium Alloy Material with a Pulsating Air Jet.Materials (Basel). 2023 Oct 23;16(20):6813. doi: 10.3390/ma16206813. Materials (Basel). 2023. PMID: 37895794 Free PMC article.
-
Brushing-induced surface roughness of two nickel based alloys and a titanium based alloy: a comparative study - in vitro study.J Int Oral Health. 2014 Jun;6(3):36-49. Epub 2014 Jun 26. J Int Oral Health. 2014. PMID: 25083031 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous