Optimizing imaging protocols for overweight and obese patients: a lutetium orthosilicate PET/CT study
- PMID: 15809482
Optimizing imaging protocols for overweight and obese patients: a lutetium orthosilicate PET/CT study
Abstract
High photon attenuation and scatter in obese patients affect image quality. The purpose of the current study was to optimize lutetium orthosilicate (LSO) PET image acquisition protocols in patients weighing > or =91 kg (200 lb).
Methods: Twenty-five consecutive patients (16 male and 9 female) weighing > or =91 kg (200 lb; range, 91-168 kg [200-370 lb]) were studied with LSO PET/CT. After intravenous injection of 7.77 MBq (0.21 mCi) of 18F-FDG per kilogram of body weight, PET emission scans were acquired for 7 min/bed position. Single-minute frames were extracted from the 7 min/bed position scans to reconstruct 1-7 min/bed position scans for each patient. Three reviewers independently analyzed all 7 reconstructed whole-body images of each patient. A consensus reading followed in cases of disagreement. Thus, 175 whole-body scans (7 per patient) were analyzed for number of hypermetabolic lesions. A region-of-interest approach was used to obtain a quantitative estimate of image quality.
Results: Fifty-nine hypermetabolic lesions identified on 7 min/bed position scans served as the reference standard. Interobserver concordance increased from 64% for 1 min/bed position scans to 70% for 3 min/bed position scans and 78% for 4 min/bed position scans. Concordance rates did not change for longer imaging durations. Region-of-interest analysis revealed that image noise decreased from 21% for 1 min/bed position scans to 14%, 13%, and 11% for, respectively, 4, 5, and 7 min/bed position scans. When compared with the reference standard, 14 lesions (24%) were missed on 1 min/bed position scans but only 2 (3%) on 4 min/bed position scans. Five minute/bed position scans were sufficient to detect all lesions identified on the 7 min/bed position scans.
Conclusion: Lesion detectability and reader concordance peaked for 5 min/bed position scans, with no further diagnostic gain achieved by lengthening the duration of PET emission scanning. Thus, 5 min/bed position scans are sufficient for optimal lesion detection with LSO PET/CT in obese patients.
Similar articles
-
Impact of patient weight and emission scan duration on PET/CT image quality and lesion detectability.J Nucl Med. 2004 May;45(5):797-801. J Nucl Med. 2004. PMID: 15136629
-
Objective and subjective comparison of standard 2-D and fully 3-D reconstructed data on a PET/CT system.Nucl Med Commun. 2007 Jul;28(7):555-9. doi: 10.1097/MNM.0b013e328194f1e3. Nucl Med Commun. 2007. PMID: 17538397
-
Optimized contrast-enhanced CT protocols for diagnostic whole-body 18F-FDG PET/CT: technical aspects of single-phase versus multiphase CT imaging.J Nucl Med. 2006 Mar;47(3):470-6. J Nucl Med. 2006. PMID: 16513616 Clinical Trial.
-
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.Semin Nucl Med. 2003 Jul;33(3):166-79. doi: 10.1053/snuc.2003.127307. Semin Nucl Med. 2003. PMID: 12931319 Review.
-
18F-NaF PET/CT of Obese Patients on a Lutetium-Yttrium Oxyorthosilicate PET/CT System: Patient Dosimetry, Optimization of Injected Activity, and Acquisition Time.J Nucl Med Technol. 2021 Jun;49(2):150-155. doi: 10.2967/jnmt.120.258137. Epub 2020 Dec 30. J Nucl Med Technol. 2021. PMID: 33380519 Review.
Cited by
-
FDG-PET/CT Imaging Predicts Histopathologic Treatment Responses after Neoadjuvant Therapy in Adult Primary Bone Sarcomas.Sarcoma. 2010;2010:143540. doi: 10.1155/2010/143540. Epub 2010 Apr 18. Sarcoma. 2010. PMID: 20414348 Free PMC article.
-
Total-Body 68Ga-PSMA-11 PET/CT for Bone Metastasis Detection in Prostate Cancer Patients: Potential Impact on Bone Scan Guidelines.J Nucl Med. 2020 Mar;61(3):405-411. doi: 10.2967/jnumed.119.230318. Epub 2019 Sep 20. J Nucl Med. 2020. PMID: 31541035 Free PMC article.
-
18F-FDG PET/CT and PET/MRI Perform Equally Well in Cancer: Evidence from Studies on More Than 2,300 Patients.J Nucl Med. 2016 Mar;57(3):420-30. doi: 10.2967/jnumed.115.158808. Epub 2016 Jan 7. J Nucl Med. 2016. PMID: 26742709 Free PMC article. Review.
-
Body weight-dependent Rubidium-82 activity results in constant image quality in myocardial perfusion imaging with PET.J Nucl Cardiol. 2021 Aug;28(4):1536-1544. doi: 10.1007/s12350-019-01875-w. Epub 2019 Sep 4. J Nucl Cardiol. 2021. PMID: 31485963
-
Optimization of injection dose in 18F-FDG PET/CT based on the 2020 national diagnostic reference levels for nuclear medicine in Japan.Ann Nucl Med. 2021 Nov;35(11):1177-1186. doi: 10.1007/s12149-021-01656-x. Epub 2021 Jul 21. Ann Nucl Med. 2021. PMID: 34287782 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical