Impact of IMRT and leaf width on stereotactic body radiotherapy of liver and lung lesions
- PMID: 15817364
- DOI: 10.1016/j.ijrobp.2004.12.075
Impact of IMRT and leaf width on stereotactic body radiotherapy of liver and lung lesions
Abstract
Purpose: The present study explored the impact of intensity-modulated radiotherapy (IMRT) on stereotactic body RT (SBRT) of liver and lung lesions. Additionally, because target dose conformity can be affected by the leaf width of a multileaf collimator (MLC), especially for small targets and stereotactic applications, the use of a micro-MLC on "uniform intensity" conformal and intensity-modulated SBRT was evaluated.
Methods and materials: The present study included 10 patients treated previously with SBRT in our institution (seven lung and three liver lesions). All patients were treated with 3 x 12 Gy prescribed to the 65% isodose level. The actual MLC-based conformal treatment plan served as the standard for additional comparison. In total, seven alternative treatment plans were made for each patient: a standard (actual) plan and an IMRT plan, both calculated with Helax TMS (Nucletron) using a pencil beam model; and a recalculated standard and a recalculated IMRT plan on Helax TMS using a point dose kernel approach. These four treatment plans were based on a standard MLC with 1-cm leaf width. Additionally, the following micro-MLC (central leaf width 3 mm)-based treatment plans were calculated with the BrainSCAN (BrainLAB) system: standard, IMRT, and dynamic arc treatments. For each treatment plan, various target parameters (conformity, coverage, mean, maximal, and minimal target dose, equivalent uniform doses, and dose-volume histogram), as well as organs at risk parameters (3 Gy and 6 Gy volume, mean dose, dose-volume histogram) were evaluated. Finally, treatment efficiency was estimated from monitor units and the number of segments for IMRT solutions.
Results: For both treatment planning systems, no significant difference could be observed in terms of target conformity between the standard and IMRT dose distributions. All dose distributions obtained with the micro-MLC showed significantly better conformity values compared with the standard and IMRT plans using a regular MLC. Dynamic arc plans were characterized by the steepest dose gradient and thus the smallest V(6 Gy) values, which were on average 7% smaller than the standard plans and 20% lower than the IMRT plans. Although the Helax TMS IMRT plans show about 18% more monitor units than the standard plan, BrainSCAN IMRT plans require approximately twice the number of monitor units relative to the standard plan. All treatment plans optimized with a pencil beam model but recalculated with a superposition method showed significant qualitative, as well as quantitative, differences, especially with respect to conformity and the dose to organs at risk.
Conclusion: Standard conformal treatment techniques for SBRT could not be improved with inversely planned IMRT approaches. Dose calculation algorithms applied in optimization modules for IMRT applications in the thoracic region need to be based on the most accurate dose calculation algorithms, especially when using higher energy photon beams.
Similar articles
-
Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributions.Radiother Oncol. 2005 Apr;75(1):106-11. doi: 10.1016/j.radonc.2005.02.007. Epub 2005 Apr 18. Radiother Oncol. 2005. PMID: 15878108 Clinical Trial.
-
Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.Phys Med Biol. 2007 Jul 7;52(13):3817-36. doi: 10.1088/0031-9155/52/13/011. Epub 2007 May 31. Phys Med Biol. 2007. PMID: 17664579
-
Effect of MLC leaf width and PTV margin on the treatment planning of intensity-modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT).Med Dosim. 2009 Summer;34(2):110-6. doi: 10.1016/j.meddos.2008.06.002. Epub 2008 Jul 1. Med Dosim. 2009. PMID: 19410139
-
Advances in treatment techniques: arc-based and other intensity modulated therapies.Cancer J. 2011 May-Jun;17(3):166-76. doi: 10.1097/PPO.0b013e31821f8318. Cancer J. 2011. PMID: 21610470 Review.
-
Issues in optimization for planning of intensity-modulated radiation therapy.Semin Radiat Oncol. 2002 Jul;12(3):210-8. doi: 10.1053/srao.2002.32434. Semin Radiat Oncol. 2002. PMID: 12118386 Review.
Cited by
-
IMRT/VMAT dose distributions generated for HD ® and Millennium ® collimators TrueBeam ® and Clinac ® accelerators.Rep Pract Oncol Radiother. 2019 Jan-Feb;24(1):20-27. doi: 10.1016/j.rpor.2018.09.001. Epub 2018 Oct 10. Rep Pract Oncol Radiother. 2019. PMID: 30337844 Free PMC article.
-
Volumetric modulated arc therapy for lung stereotactic radiation therapy can achieve high local control rates.Radiat Oncol. 2014 Nov 11;9:243. doi: 10.1186/s13014-014-0243-1. Radiat Oncol. 2014. PMID: 25385062 Free PMC article.
-
Characterization of a novel VenusX orthogonal dual-layer multileaf collimator.J Appl Clin Med Phys. 2024 May;25(5):e14357. doi: 10.1002/acm2.14357. Epub 2024 Apr 15. J Appl Clin Med Phys. 2024. PMID: 38620027 Free PMC article.
-
Is 5 mm MMLC suitable for VMAT-based lung SBRT? A dosimetric comparison with 2.5 mm HDMLC using RTOG-0813 treatment planning criteria for both conventional and high-dose flattening filter-free photon beams.J Appl Clin Med Phys. 2015 Jul 8;16(4):112–124. doi: 10.1120/jacmp.v16i4.5415. J Appl Clin Med Phys. 2015. PMID: 26219006 Free PMC article.
-
Dosimetric impact of multileaf collimator leaf width according to sophisticated grade of technique in the IMRT and VMAT planning for pituitary adenoma lesion.Oncotarget. 2016 Nov 22;7(47):78119-78126. doi: 10.18632/oncotarget.12974. Oncotarget. 2016. PMID: 27806336 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical