. 2005 Jun;94(3):228-34.
doi: 10.1007/s00421-004-1300-5. Epub 2005 May 26.

Reliability of peak VO(2) and maximal cardiac output assessed using thoracic bioimpedance in children

Affiliations

Reliability of peak VO(2) and maximal cardiac output assessed using thoracic bioimpedance in children

Joanne Welsman et al. Eur J Appl Physiol. 2005 Jun.

Abstract

The purpose of this study was to evaluate the reliability of a thoracic electrical bioimpedance based device (PhysioFlow) for the determination of cardiac output and stroke volume during exercise at peak oxygen uptake (peak VO(2) in children. The reliability of peak VO(2) is also reported. Eleven boys and nine girls aged 10-11 years completed a cycle ergometer test to voluntary exhaustion on three occasions each 1 week apart. Peak VO(2) was determined and cardiac output and stroke volume at peak VO(2) were measured using a thoracic bioelectrical impedance device (PhysioFlow). The reliability of peak VO(2) cardiac output and stroke volume were determined initially from pairwise comparisons and subsequently across all three trials analysed together through calculation of typical error and intraclass correlation. The pairwise comparisons revealed no consistent bias across tests for all three measures and there was no evidence of non-uniform errors (heteroscedasticity). When three trials were analysed together typical error expressed as a coefficient of variation was 4.1% for peak VO(2) 9.3% for cardiac output and 9.3% for stroke volume. Results analysed by sex revealed no consistent differences. The PhysioFlow method allows non-invasive, beat-to-beat determination of cardiac output and stroke volume which is feasible for measurements during maximal exercise in children. The reliability of the PhysioFlow falls between that demonstrated for Doppler echocardiography (5%) and CO(2) rebreathing (12%) at maximal exercise but combines the significant advantages of portability, lower expense and requires less technical expertise to obtain reliable results.

PubMed Disclaimer

References

    1. Sports Med. 1998 Oct;26(4):217-38 - PubMed
    1. Acta Anaesthesiol Scand. 1995 Feb;39(2):245-51 - PubMed
    1. Sports Med. 2002;32(15):973-86 - PubMed
    1. J Pediatr. 1978 Jul;93(1):62-6 - PubMed
    1. Eur J Appl Physiol. 2000 Jul;82(4):313-20 - PubMed

Publication types