Design and implementation of dynamic near-infrared optical tomographic imaging instrumentation for simultaneous dual-breast measurements
- PMID: 15835360
- DOI: 10.1364/ao.44.002140
Design and implementation of dynamic near-infrared optical tomographic imaging instrumentation for simultaneous dual-breast measurements
Abstract
Dynamic near-infrared optical tomographic measurement instrumentation capable of simultaneous bilateral breast imaging, having a capability of four source wavelengths and 32 source-detector fibers for each breast, is described. The system records dynamic optical data simultaneously from both breasts, while verifying proper optical fiber contact with the tissue through implementation of automatic schemes for evaluating data integrity. Factors influencing system complexity and performance are discussed, and experimental measurements are provided to demonstrate the repeatability of the instrumentation. Considerations in experimental design are presented, as well as techniques for avoiding undesirable measurement artifacts, given the high sensitivity and dynamic range (1:10(9)) of the system. We present exemplary clinical results comparing the measured physiologic response of a healthy individual and of a subject with breast cancer to a Valsalva maneuver.
Similar articles
-
Three-dimensional nonlinear optical endoscopy.J Biomed Opt. 2007 Jul-Aug;12(4):040501. doi: 10.1117/1.2756102. J Biomed Opt. 2007. PMID: 17867789
-
Optical imaging of breast cancer using hemodynamic changes induced by valsalva maneuver.Rofo. 2013 Apr;185(4):358-66. doi: 10.1055/s-0032-1330446. Epub 2013 Mar 14. Rofo. 2013. PMID: 23494503
-
Wavelength band optimization in spectral near-infrared optical tomography improves accuracy while reducing data acquisition and computational burden.J Biomed Opt. 2008 Sep-Oct;13(5):054037. doi: 10.1117/1.2976425. J Biomed Opt. 2008. PMID: 19021417 Free PMC article.
-
Optical tomographic imaging of small animals.Curr Opin Biotechnol. 2005 Feb;16(1):79-88. doi: 10.1016/j.copbio.2005.01.002. Curr Opin Biotechnol. 2005. PMID: 15722019 Review.
-
Recent advances in diffuse optical imaging.Phys Med Biol. 2005 Feb 21;50(4):R1-43. doi: 10.1088/0031-9155/50/4/r01. Phys Med Biol. 2005. PMID: 15773619 Review.
Cited by
-
Hierarchical Bayesian modeling of the relationship between task-related hemodynamic responses and cortical excitability.Hum Brain Mapp. 2023 Feb 15;44(3):876-900. doi: 10.1002/hbm.26107. Epub 2022 Oct 17. Hum Brain Mapp. 2023. PMID: 36250709 Free PMC article.
-
Optimizing spatial accuracy in electroencephalography reconstruction through diffuse optical tomography priors in the auditory cortex.Biomed Opt Express. 2024 Jul 29;15(8):4859-4876. doi: 10.1364/BOE.531576. eCollection 2024 Aug 1. Biomed Opt Express. 2024. PMID: 39347003 Free PMC article.
-
Functional Near-Infrared Spectroscopy as a Target Navigator for rTMS Modulation in Patients with Hemiplegia: A Randomized Control Study.Neurol Ther. 2022 Mar;11(1):103-121. doi: 10.1007/s40120-021-00300-0. Epub 2021 Nov 13. Neurol Ther. 2022. PMID: 34773596 Free PMC article.
-
A review of optical breast imaging: Multi-modality systems for breast cancer diagnosis.Eur J Radiol. 2020 Aug;129:109067. doi: 10.1016/j.ejrad.2020.109067. Epub 2020 May 18. Eur J Radiol. 2020. PMID: 32497943 Free PMC article. Review.
-
Evaluation of a personalized functional near infra-red optical tomography workflow using maximum entropy on the mean.Hum Brain Mapp. 2021 Oct 15;42(15):4823-4843. doi: 10.1002/hbm.25566. Epub 2021 Aug 3. Hum Brain Mapp. 2021. PMID: 34342073 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical