Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Apr;18(4):299-305.
doi: 10.1016/j.echo.2004.11.002.

Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: a validation study compared with magnetic resonance imaging

Affiliations
Comparative Study

Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: a validation study compared with magnetic resonance imaging

Liping Bu et al. J Am Soc Echocardiogr. 2005 Apr.

Abstract

Objective: We sought to assess the feasibility, accuracy, and reproducibility of a rapid full volume acquisition strategy using real-time (RT) 3-dimensional (3D) echocardiography (3DE) for measurement of left ventricular (LV) volumes, mass, stroke volume (SV), and ejection fraction (EF) in children.

Methods: A total of 19 healthy children (mean 10.6 +/- 2.8 years, 11 male and 9 female) were prospectively enrolled in this study. RT 3DE was performed using an ultrasound system to acquire full volume 3D dataset from the apical window with electrocardiographic triggering in 8 s/dataset. The images were processed offline using software. The LV endocardial and epicardial borders were traced manually to derive LV end-systolic volume, end-diastolic volume, mass, SV, and EF. Magnetic resonance imaging (MRI) studies were performed on a 1.5-T scanner using a breath hold 2-dimensional cine-FIESTA (fast imaging employing steady-state acquisition) sequence.

Results: All RT 3DE and MRI data were acquired successfully for analysis. Measurements of LV end-systolic volume, end-diastolic volume, mass, SV, and EF by RT 3DE correlated well by Pearson regression ( r = 0.86-0.97, P < .001) and agreed well by Bland-Altman analysis with MRI. The interobserver and intraobserver variability of RT 3DE measurements were less than 5%.

Conclusions: This prospective study demonstrated that RT 3DE measurements of LV end-systolic volume, end-diastolic volume, mass, SV, and EF in children using rapid full volume acquisition strategy are feasible, accurate, and reproducible and are comparable with MRI measurements.